Magnetic Resonance Imaging Parameters Selected for Optimal Visualization of the Occipitoatlantal Interspace
The Journal of the American Osteopathic Association
|February 26, 2019
Summary
New MR imaging protocols can visualize rectus capitis posterior minor muscles for chronic headache research. This method allows for accurate assessment of occipitoatlantal structures and their changes over time.
Area of Science:
- Medical Imaging
- Musculoskeletal System Anatomy
- Neurology
Background:
- Disorders of the rectus capitis posterior minor (RCPm) muscles are linked to chronic headaches.
- Current MRI protocols lack the detail to assess occipitoatlantal structures or their time-dependent changes.
Purpose of the Study:
- Develop an advanced MRI protocol for superior visualization of occipitoatlantal soft tissues.
- Enable precise quantification of time-dependent pathological changes in these structures.
Main Methods:
- Recruited asymptomatic participants for MRI scans at enrollment and 2 weeks later.
- Utilized a 3T magnet and a spin-echo sequence to acquire T1-weighted axial images.
- Aligned images perpendicular to RCPm muscles for accurate cross-sectional area (CSA) quantification.
Main Results:
- No significant differences were observed in RCPm muscle CSA between enrollment and 2-week follow-up.
- This indicates the stability of these muscles within the study timeframe.
Conclusions:
- The developed MRI protocol provides high-quality imaging of occipitoatlantal structures.
- This enables reliable comparison of functional morphology at different time points.
Related Concept Videos
Magnetic Resonance Imaging
9.3K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.3K
Imaging Studies IV: Magnetic Resonance Imaging
271
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
271
Atomic Nuclei: Magnetic Resonance
1.2K
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
Nuclear Magnetic Resonance (NMR): Overview
6.9K
Nuclear magnetic resonance (NMR) is a phenomenon exhibited by certain nuclei that can absorb characteristic radio frequency radiation under certain conditions. NMR has been extensively applied in molecular spectroscopy and medical diagnostic imaging. In both these applications, the molecule or subject under study is placed in a magnetic field and irradiated with radio frequency energy.
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
6.9K
Resonance
65.1K
The Lewis structure of a nitrite anion (NO2−) may actually be drawn in two different ways, distinguished by the locations of the N-O and N=O bonds.
65.1K
Wave Parameters
9.3K
The simplest mechanical waves are associated with simple harmonic motion and repeat themselves for several cycles. These simple harmonic waves can be modeled using a combination of sine and cosine functions. Consider a simplified surface water wave that moves across the water's surface. Unlike complex ocean waves, in surface water waves, water moves vertically, oscillating up and down, whereas the disturbance of the wave moves horizontally through the medium. If a seagull is floating on the...
9.3K