Electron beam damage of epoxy resin films studied by scanning transmission X-ray spectromicroscopy
Weiwei Zhang1, Lis G de A Melo2, Adam P Hitchcock2
1Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada.
Abstract:
Focused ion beam coupled with scanning electron microscopy (FIB-SEM) is a popular technique for advanced electron microscopy with applications such as, high-precision site-specific lamella sample preparation for transmission electron microscopy (TEM) and slice-and-view FIB 3-dimensional tomography. Damage caused by the electron imaging component of FIB-SEM may be compounded with damage from the ions during the ion milling process. There are known strategies for mitigating damage from ions and electrons (cryo-SEM, dose-control, voltage control), but the electron damage on common embedding resins for EM has not been explored in detail beyond their resistance to shape-change. The relationship between beam parameters and damage mechanisms remains unclear. Since we are relying on the physical, chemical and thermal stability of embedded samples during ion-beam milling, it is important to distinguish electron beam damage from ion beam damage. Scanning transmission X-ray microscopy (STXM) has been used for analyzing the electron beam radiation damage on polymer films by characterizing the chemical bonding changes. In this paper, we focus on the effect of beam voltage and electron dose on electron beam damage to epoxy resin thin films. Irradiated areas on polymer thin films were characterized by near edge X-ray absorption fine structure (NEXAFS) in STXM. We found that, even when using low current and voltage, the electron beam can still cause noticeable chemical changes within the polymer film. The degree of electron beam damage depends not only on the beam energy, but also on the amount of inelastic scattering occurring within the material, as determined by the sample thickness.
Related Concept Videos
Transmission Electron Microscopy
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Leaky Scanning