Related Experiment Video
Updated: Jan 28, 2026

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Feasibility of Image Registration for Ultrasound-Guided Prostate Radiotherapy Based on Similarity Measurement by a
Ning Zhu1,2, Mohammad Najafi2,3, Bin Han2,4
11 Google, Santa Clara County, CA, USA.
Purpose:
Registration of 3-dimensional ultrasound images poses a challenge for ultrasound-guided radiation therapy of the prostate since ultrasound image content changes significantly with anatomic motion and ultrasound probe position. The purpose of this work is to investigate the feasibility of using a pretrained deep convolutional neural network for similarity measurement in image registration of 3-dimensional transperineal ultrasound prostate images.
Methods:
We propose convolutional neural network-based registration that maximizes a similarity score between 2 identical in size 3-dimensional regions of interest: one encompassing the prostate within a simulation (reference) 3-dimensional ultrasound image and another that sweeps different spatial locations around the expected prostate position within a pretreatment 3-dimensional ultrasound image. The similarity score is calculated by (1) extracting pairs of corresponding 2-dimensional slices (patches) from the regions of interest, (2) providing these pairs as an input to a pretrained convolutional neural network which assigns a similarity score to each pair, and (3) calculating an overall similarity by summing all pairwise scores. The convolutional neural network method was evaluated against ground truth registrations determined by matching implanted fiducial markers visualized in a pretreatment orthogonal pair of x-ray images. The convolutional neural network method was further compared to manual registration and a standard commonly used intensity-based automatic registration approach based on advanced normalized correlation.
Results:
For 83 image pairs from 5 patients, convolutional neural network registration errors were smaller than 5 mm in 81% of the cases. In comparison, manual registration errors were smaller than 5 mm in 61% of the cases and advanced normalized correlation registration errors were smaller than 5 mm only in 25% of the cases.
Conclusion:
Convolutional neural network evaluation against manual registration and an advanced normalized correlation -based registration demonstrated better accuracy and reliability of the convolutional neural network. This suggests that with training on a large data set of transperineal ultrasound prostate images, the convolutional neural network method has potential for robust ultrasound-to-ultrasound registration.
Related Concept Videos
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Causes of Similarity-Dissimilarity Effect
Convolution Properties I
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output:
Factors Influencing Attraction III: Similarity
Protein Networks
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...
Protein Networks