Related Experiment Video
Updated: Jan 28, 2026

Neuronavigation-guided Repetitive Transcranial Magnetic Stimulation for Aphasia
Published on: May 6, 2016
Neuronavigated Versus Non-navigated Repetitive Transcranial Magnetic Stimulation for Chronic Tinnitus: A Randomized
Hanna Sahlsten1, Anu Holm2, Esa Rauhala2
11 Faculty of Medicine, University of Turku, Finland.
Abstract:
Repetitive transcranial magnetic stimulation (rTMS) has shown variable effect on tinnitus. A prospective, randomized 6-month follow-up study on parallel groups was conducted to compare the effects of neuronavigated rTMS to non-navigated rTMS in chronic tinnitus. Forty patients (20 men, 20 women), mean age of 52.9 years (standard deviation [ SD] = 11.7), with a mean tinnitus duration of 5.8 years ( SD = 3.2) and a mean tinnitus intensity of 62.2/100 ( SD = 12.8) on Visual Analog Scale (VAS 0-100) participated. Patients received 10 sessions of 1-Hz rTMS to the left temporal area overlying auditory cortex with or without neuronavigation. The main outcome measures were VAS scores for tinnitus intensity, annoyance, and distress, and Tinnitus Handicap Inventory (THI) immediately and at 1, 3, and 6 months after treatment. The mean tinnitus intensity (hierarchical linear mixed model: F3 = 7.34, p = .0006), annoyance ( F3 = 4.45, p = .0093), distress ( F3 = 5.04, p = .0051), and THI scores ( F4 = 17.30, p < .0001) decreased in both groups with non-significant differences between the groups, except for tinnitus intensity ( F3 = 2.96, p = .0451) favoring the non-navigated rTMS. Reduction in THI scores persisted for up to 6 months in both groups. Cohen's d for tinnitus intensity ranged between 0.33 and 0.47 in navigated rTMS and between 0.55 and 1.07 in non-navigated rTMS. The responder rates for VAS or THI ranged between 35% and 85% with no differences between groups ( p = .054-1.0). In conclusion, rTMS was effective for chronic tinnitus, but the method of coil localization was not a critical factor for the treatment outcome.
More Related Videos
09:16Study Design for Navigated Repetitive Transcranial Magnetic Stimulation for Speech Cortical Mapping
Published on: March 24, 2023
10:15Utilizing Repetitive Transcranial Magnetic Stimulation to Improve Language Function in Stroke Patients with Chronic Non-fluent Aphasia
Published on: July 2, 2013
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Randomized Experiments
Simple randomization
Simple...
Random and Systematic Errors
Random Sampling Method