Fluoroscopic Cranial Radiation Exposure in Spine Surgery: A Prospective Single-Center Evaluation in Operating Room
Laila Malani Mohammad1, James Messegee1, M Omar Chohan1
1Department of Neurosurgery, University of New Mexico School of Medicine, Albuquerque, New Mexico.
Background:
Cranial radiation exposure during instrumented spine surgery is not well documented. We set out to measure this risk to the patient, surgeon, surgical resident, and scrub technician during these procedures.
Methods:
Forty-seven individuals were enrolled during a 1.5-year period between October 2014 and March 2016 at the University of New Mexico Department of Neurosurgery. Radiation doses were obtained through electronic dosimeters placed on the surgical cap over the temporal scalp (bilaterally on surgeon and resident assist, unilaterally on surgical scrub on the side facing radiation source) and on the midline of the patient's exposed cranium.
Results:
Of the 47 procedures, 39 (83%) were open and 8 (17%) were minimally invasive or percutaneous instrumented procedures. A total of 91 motion segments were treated, with a mean of 1.9 levels per case (57% lumbosacral, 34% cervical, and 2.1% thoracic). Total fluoroscopic time was 12.9 minutes. Mean dose per case (mrem/case) was calculated for the spine surgeon (1.4), resident assist (1.4), surgical scrub (1.2), and the patient (3.6). All doses were within federal safety guidelines. A spine surgeon would need to perform more than 1400 cases per year to reach the current federal maximum permissible dose for head exposure.
Conclusions:
There was no difference in cranial radiation exposure between operating room staff during spine surgeries. Moreover, the doses measured at the cranium were within national safety limits. Current protective technologies have significantly reduced the amount of ionizing radiation exposure during routine spine procedures; however, changes in behavior or equipment may further reduce radiation exposure to health care workers.
Clinical Relevance:
Radiation exposure to patients and hospital staff remains a major concern in the practice of modern spine surgery. Cranial exposure remains the only established environmental risk factor for brain tumors, such as gliomas and meningiomas. Our study shows that all those exposed to radiation during spine surgery had cranial doses well within the national safety limits.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
09:07An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
Related Concept Videos
Biological Effects of Radiation
Lattice Centering and Coordination Number
Types of Unit Cells
Imagine taking a large number of identical...
Radiation: Applications
The average...
Center of Gravity
Center of Gravity
To determine its location, the principle of moments can be utilized by dividing the object into...
Center of Mass
The knowledge of the center of mass can also help us to describe and predict the motion of objects. For example, when a ball is thrown...