Gas-Phase Hydrogen/Deuterium Scrambling in Negative-Ion Mode Tandem Mass Spectrometry

Qingyi Wang1, Nicholas B Borotto2, Kristina Håkansson3

  • 1Department of Chemistry, University of Michigan, 930 N University Avenue, Ann Arbor, MI, 48109-1055, USA.

Related Concept Videos

Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2.5K
Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
8.4K
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.7K
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume03:43

Applications of the Ideal Gas Law: Molar Mass, Density, and Volume

The volume occupied by one mole of a substance is its molar volume. The ideal gas law, PV = nRT,  suggests that the volume of a given quantity of gas and the number of moles in a given volume of gas vary with changes in pressure and temperature. At standard temperature and pressure, or STP (273.15 K and 1 atm), one mole of an ideal gas (regardless of its identity) has a volume of about 22.4 L — this is referred to as the standard molar volume.
63.3K
Mass Spectrometry: Overview01:19

Mass Spectrometry: Overview

Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electron ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave behind a...
8.6K
Mass Spectrometry of Amines01:15

Mass Spectrometry of Amines

In mass spectroscopy, amines undergo fragmentation to give parent ions with odd molecule weights. This observed mass spectrum follows the nitrogen rule; a molecule with an odd number of nitrogen atoms produces a molecular ion with an odd molecular weight. Amines undergo fragmentation through α cleavage, producing nitrogen-containing cations—iminium ions—and alkyl radicals. Mass spectra of aromatic and cyclic aliphatic amines exhibit strong molecular ion peaks, but acyclic...
5.4K