Related Experiment Video
Updated: Jan 28, 2026

In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
An In Vitro Blood Flow Loop System for Evaluating the Thrombogenicity of Medical Devices and Biomaterials
Megan A Jamiolkowski1, Matthew C Hartung, Richard A Malinauskas
1From the U.S. Food and Drug Administration (FDA), Center for Devices and Radiological Health (CDRH), Office of Science and Engineering Laboratories (OSEL), Silver Spring, Maryland.
Abstract:
A reliable in vitro dynamic test method to evaluate device thrombogenicity is very important for the improvement of the design and safety of blood-contacting medical devices, while reducing the use of animal studies. In this study, a recirculating flow loop system was developed for thrombogenicity testing, using donor sheep blood anticoagulated with Anticoagulant Citrate Dextrose Solution A (ACDA) and used within 24-36 hr postdraw. Immediately before testing, the blood was recalcified and heparinized to a donor-specific target concentration. The heparinization level was based on a static pretest, in which latex tubes were incubated at room temperature for 30 min in blood with a series of heparin concentrations and evaluated for thrombus deposition. For dynamic testing, blood was recirculated at room temperature through a polyvinyl chloride (PVC) tubing loop containing a test material for 1 hr at 200 ml/min using a roller pump. Nine materials were investigated: a negative control (polytetrafluoroethylene [PTFE]), a positive control (latex), and seven commonly used biomaterials including PVC, two silicones with different formulations (Q-Sil and V-Sil), nylon, polyurethane (PU), high-density polyethylene (HDPE), and polyether block amide (PEBAX). The results showed that latex was significantly more thrombogenic than all the other materials (p < 0.05), PVC and Q-Sil exhibited intermediate thrombogenicity with significantly more thrombus surface coverage and thrombus weight than PTFE (p < 0.05), whereas PTFE and the rest of the biomaterials had little to no thrombus deposition. In summary, the test loop system was able to effectively differentiate materials with different thrombogenic potentials.
More Related Videos
08:44An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
09:41Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow
Published on: March 5, 2020
Related Concept Videos
Blood Flow
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Applications of Integration to Find Blood Flow
Inhaled Medications
Feedback Loops
Physiology of the Genitourinary System I: Renal Blood Flow and Glomerular Filtration