Related Experiment Video
Updated: Jan 28, 2026

Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Left-Sided Ventricular-arterial Coupling and Volume Responsiveness in Septic Shock Patients
Suwei Li1, Xianyao Wan1, Krzysztof Laudanski2
1Department of Critical Care Medicine, First Hospital affiliated to Dalian Medical University, Dalian, People's Republic of China.
Background:
Suboptimal ventricular arterial coupling (VAC) is one of the pivotal determinants of inefficient heart performance despite appropriate administration of fluids or vasopressors in shocks. Here, we investigate the performance of VAC in patients who are unresponsive to fluid administration in septic shock.
Methods:
This is a retrospective observational study of septic shock patients (n = 35). VAC was evaluated by effective arterial elastance (EaI), left ventricular end-systolic elastance (EesI), and EaI/EesI. Septic shock patients successfully fluid resuscitated after pulse indicator continuous cardiac output (PiCCO) monitoring, defined as an increase in general end-diastolic ventricular volume (GEDVI) more than 10%, were divided into volume responsive (VVr), and volume unresponsive (VVur) groups based on a cardiac index increase above 10%. We hypothesize that two groups of patients will exhibit dissimilarities of VAC variation, defined as EaI/EesI variation (ΔEaI/EesI).
Results:
Variations of EaI (ΔEaI), and EaI/EesI (ΔEaI/EesI), and systemic vascular resistance index (ΔSVRI) were significantly lower in the VVr group than those in the VVur group (P < 0.05). Variations of cardiac index (ΔCI), stroke volume index (ΔSVI), and EesI (ΔEesI) were significantly higher in patients with ΔEaI/EesI ≤ 0. Concomitantly, ΔEaI and ΔSVRI were significantly diminished as compared with patients with ΔEaI/EesI > 0 (P < 0.05). ΔCI has an inverse relationship with both ΔEaI (r = -0.46, P = 0.006), ΔEaI/EesI (r = -0.65, P < 0.001), and ΔSVRI (r = -0.59, P < 0.001). We observed more patients who were fluid responsive in the ΔEaI/EesI ≤ 0 group than in the group with ΔEaI/EesI > 0 (88.89% vs. 26.92%, P = 0.01).
Conclusions:
Variation of VAC is often related to suboptimal ventricular volume responsiveness among patients with septic shock.
More Related Videos
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
07:02A Large Animal Model for Pulmonary Hypertension and Right Ventricular Failure: Left Pulmonary Artery Ligation and Progressive Main Pulmonary Artery Banding in Sheep
Published on: July 15, 2021
Related Concept Videos
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...
G-protein Coupled Receptors
Spin–Spin Coupling: One-Bond Coupling
Constant Volume Calorimetry