Evaluation of choroidal thickness in amblyopia using optical coherence tomography
Yi Zha1, Jinfei Zhuang1, Wangqiang Feng1
1Department of Ophthalmology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China.
Objective:
To investigate the choroidal thickness in children with amblyopia through spectral-domain optical coherence tomography.
Methods:
A total of 31 children with unilateral amblyopia and 31 right eyes of controls with normal vision were enrolled in the study. The choroidal thickness was measured directly below the fovea and at 12 other locations: 1, 2 and 3 mm superior, temporal, inferior, and nasal to the fovea. All the parameters were compared between amblyopic eyes, fellow eyes, and control eyes.
Results:
The mean subfoveal choroidal thickness was 398.03 ± 74.60, 354.13 ± 81.78, and 328.12 ± 65.93 μm in amblyopic eyes, fellow eyes, and control eyes, respectively. Significant difference was found in choroidal thickness among three groups at subfoveal choroidal thickness, N1, and S1 using multivariate analysis of covariance after adjusting for axial length. Significant negative correlation was found only between subfoveal choroidal thickness and axial length in amblyopic eyes (r = -0.463, p = 0.01).
Conclusion:
The subfoveal choroid is significantly thicker in amblyopic eyes than control eyes only at subfoveal choroidal thickness, N1, and S1. The choroidal thickness was thickest in the subfoveal region and thinnest in the nasal region. There are other changes in choroidal structure associated with amblyopia.
More Related Videos
11:21Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
Published on: January 15, 2013
03:47Retinal and Choroidal Thickness Changes in Populations with Helicobacter pylori Infection by Swept-Source Optical Coherence Tomography
Published on: November 1, 2024
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Properties of Enantiomers and Optical Activity
Imaging Studies III: Computed Tomography