Single-center evaluation of a next generation fully repositionable and retrievable transcatheter aortic valve
Karolina Berntorp1, Sasha Koul2, Shahab Nozohoor2
1Department of Cardiology, Clinical Sciences, Lund University, Skane University Hospital, 221-85, Lund, SE, Sweden. karolina.berntorp@med.lu.se.
Background:
The mechanically expandable Lotus Valve System is a fully repositionable and retrievable valve with an adaptive seal to minimize paravalvular leak (PVL). The aim of this study was to evaluate the short- and long-term safety and efficacy of the new device with focus on a new implantation technique to reduce the need for a permanent pacemaker (PPM) post procedure.
Methods:
We performed a prospective single-center, non-randomized evaluation of the Lotus Valve System. The first 100 consecutive Lotus Valve implantations were included in the analysis. Outcome was assessed according to VARC2-criteria. Postoperative pacemaker rates were assessed using the national pacemaker registry and electronic medical records. Mortality at 30 days and 12 months were acquired from the national population registry.
Results:
Mean age was 82.7 ± 5.6 years, mean Euroscore I was 25.3 ± 14.5%, mean STS-score was 6.5 ± 4.1% and mean aortic valve area was 0.6 ± 0.1 cm2. There were no cases of valve embolization, ectopic valve deployment or additional valve implantation. Device success according to the VARC2-criteria was 97%. The 30-day mortality rate was 3%. Two deaths occurred due to stroke and one due to a ventricular rupture. Major stroke rate was 2% and major vascular complication rate was 2%. The 12-month mortality rate was 14%. At discharge 87% of patients had no/trace PVL, 12% had mild PVL and one patient had a moderate PVL. A total of 13% received a new PPM post valve implantation. Among patients who did not have a PPM before the procedure, the PPM rate was 15.3%.
Conclusions:
This single-center evaluation of the Lotus Valve System demonstrated a good clinical outcome with a low mortality, in a high-risk population. Introduction of a new implantation technique resulted in lower PPM rates than previously reported without negatively affecting PVL.
Trial Registration:
Current Controlled Trials ISRCTN14952278 , retrospectively registered 06/11/2017.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Retrieval
Recall involves accessing information without cues, such as during an essay test, where individuals must retrieve facts and concepts from memory unaided. Another example is remembering the name of a colleague...
ER Retrieval Pathway
The ER uses many checkpoints to prevent the entry of incorrectly folded or a resident protein as cargo onto a transport vesicle. These mechanisms...
Lattice Centering and Coordination Number
Types of Unit Cells
Imagine taking a large number of identical...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Center of Gravity
Center of Gravity
To determine its location, the principle of moments can be utilized by dividing the object into...