Related Experiment Video
Updated: Jan 28, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Post-Column Make-Up Flow (PCMF) Enhances the Performance of Capillary-Flow PGC-LC-MS/MS-Based Glycomics
Hannes Hinneburg, Sayantani Chatterjee, Falko Schirmeister
1Analytics Group , Bioprocessing Technology Institute, A*STAR , Singapore 138668 , Singapore.
Abstract:
Deep characterization of biologically relevant glycans remains challenging. Porous graphitized carbon-liquid chromatography tandem mass spectrometry (PGC-LC-MS/MS) enables the quantitative elucidation of glycan fine structures. However, the early PGC-LC elution of smaller glycans (tri-, tetra-, and pentasaccharides) at low organic solvent content hampers their detection. In efforts to improve the glycan profiling sensitivity and accuracy, we present a new capillary-flow PGC-LC-MS/MS-based configuration comprising a post-column make-up flow (PCMF) that supplies an ion-promoting organic solvent to separated glycans prior to their detection by MS. The analytical performance of this setup was systematically evaluated against our existing capillary-flow PGC-LC-MS/MS platform (Jensen et al., Nat. Protoc. 2012, 7, 1299). Specifically, the ion intensities and signal-to-noise ratios of various classes of nonderivatized glycans from N- and O-glycoproteins and fructooligosaccharide mixtures were compared using methanol (MeOH)-, isopropanol (IPA)-, and acetonitrile (ACN)-based PCMF at various concentrations. In particular, ACN- and IPA-based PCMF dramatically increased the signal response across all glycan types (30- to 100-fold), improved the MS/MS spectral quality, and reduced the quantitative glycoprofile variation between replicates. In particular, the detection of the early eluting glycans benefitted from the PCMF. The highest sensitivity gains were achieved with the supplements of 100% ACN and IPA (equating to 57% (v/v) net concentration at the ion source) while neither compromising the favorable PGC-LC properties including the high peak capacity and glycan isomer separation nor changing the MS detection behavior. In conclusion, PCMF-based PGC-LC-MS/MS dramatically improves the glycomics sensitivity, coverage, and quantitative accuracy not least for the difficult-to-detect early eluting and low-abundance glycans detached from N- and O-glycoproteins.
More Related Videos
Related Concept Videos
Gene Flow
Flow Cytometry
In...
Flow Sheet
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation:
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Irrotational Flow
Turbulent Flow

