Related Experiment Video
Updated: Jan 28, 2026

Detection of Glycosaminoglycans by Polyacrylamide Gel Electrophoresis and Silver Staining
Published on: February 25, 2021
Immuno-gold silver staining assays on capillary-driven microfluidics for the detection of malaria antigens
Ngoc M Pham1, Sebastian Rusch2,3,4, Yuksel Temiz5
1ETH Zürich, Mobile Health Systems Lab, Department of Health Sciences and Technology, BAA, Institute of Robotics and Intelligent Systems, Lengghalde 5, CH-8092, Zürich, Switzerland.
Abstract:
Accurate and affordable rapid diagnostic tests (RDTs) are indispensable but often lacking for many infectious diseases. Specifically, there is a lack of highly sensitive malaria RDTs that can detect low antigen concentration at the onset of infection. Here, we present a strategy to improve the sensitivity of malaria RDTs by using capillary-driven microfluidic chips and combining sandwich immunoassays with electroless silver staining. We used 5 μm fluorescent beads functionalized with capture antibodies (cAbs). These beads are self-assembled by capillary action in recessed "bead lanes", which cross the main flow path of chips microfabricated in Si and SU-8. The binding of analytes to detection antibodies (dAbs) and secondary antibodies (2ndAbs) conjugated to gold nanoparticles (NPs) allows the formation of a silver film on the beads. Such silver film masks the fluorescent core of the bead inversely proportional to the concentration of antigen in a sample. We illustrate this method using the recombinant malaria antigen Plasmodium falciparum histidine-rich-protein 2 (rPfHRP2) spiked in human serum. This antigen was a recombinant HRP2 protein expressed in Escherichia coli, which is also the standard reference material. The limit of detection (LOD) of our immunoassay was found to be less than 6 ng mL-1 of rPfHRP2 within 20 min, which is approaching the desired sensitivity needed in the Target Product Profile (TPP) for malaria elimination settings. The concept presented here is flexible and may also be utilized for implementing fluorescence immunoassays for the parallel detection of biomarkers on capillary-driven microfluidic chips.
Related Concept Videos
Capillary Beds
Capillaries connect arterioles, small branches of arteries, to venules,...
Capillary Exchange
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Capillaries and Their Types
Capillary Electrophoresis: Instrumentation
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...

