Comparison of the Automated with the Semi-Automatic Coulter Counter Method and the Direct Microscopic Somatic Cell
R E Ginn1, V S Packard1, D R Thompson1
1Dairy Quality Control Institute, Inc., St. Paul, Minnesota 55113, and Departments of Food Science and Nutrition and Agricultural Engineering, University of Minnesota, St. Paul, Minnesota 55108.
Abstract:
The automatic Milk Cell Counter (MCC) and semi-automatic electronic cell counter (ESCC) of Coulter Electronics were compared with each other and with the direct microscopic cell count (DMSCC) on raw milk samples with various cell counts. The average DMSCC count on 241 samples of milk with Wisconsin Mastitis Test (WMT) results of 22 mm and higher was 55,000 cells/ml above the average MCC count when calibrated to a 4.4-μm minimum particle diameter. This difference is statistically significant at the 1% level. On 24 different raw milk samples of widely varying somatic cell count analyzed in replicate six times per sample, the standard deviations for replicate samples were 34,300, 34,900 and 136,000 for the MCC, ESCC and DMSCC, respectively. For these tests, the MCC had been calibrated to a 4.3-μm minimum particle diameter. The average difference between counts by the MCC and ESCC methods was only 6080/ml, but this was statistically significant at the 5% level. The average MCC count with the equipment set at 4.3-μm minimum particle diameter was 58,000 above the average DMSCC count.
Related Concept Videos
Automatic Processing and Automatic Social Behavior
Somatic to iPS Cell Reprogramming
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Convenience Sampling Method
Convenience sampling is a non-random method of sample selection; this method selects individuals that are easily accessible and may result in biased data. For example, a marketing...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Cancers Originate from Somatic Mutations in a Single Cell