Related Experiment Video
Updated: Jan 28, 2026

Stress-induced Antibiotic Susceptibility Testing on a Chip
Published on: January 8, 2014
Evaluation of the MicroScan Colistin Well and Gradient Diffusion Strips for Colistin Susceptibility Testing in
Joseph D Lutgring1,2, Anny Kim3, Davina Campbell3
1Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, Atlanta, Georgia, USA yix4@cdc.gov.
Abstract:
Many laboratories are unable to perform colistin susceptibility testing. Diffusion-based antimicrobial susceptibility testing methods are not recommended, and not all laboratories have the capacity to perform broth microdilution (BMD). Using a multistep tiered approach, we investigated whether the adapted use of the MicroScan colistin well (4 μg/ml) could enhance laboratory capacity for the detection and subsequent molecular characterization of colistin-resistant Enterobacteriaceae For the MicroScan colistin well, categorical agreement with BMD was 92.7%, and the very major error rate was 10.7%. For gradient diffusion strips, the categorical agreement was 86.4%, and the very major error rate was 53.6%. The MicroScan colistin well detected all isolates carrying mcr-1 or mcr-2 genes (n = 16), but gradient diffusion strips identified an MIC of ≥4 for colistin for only 62.5% of these isolates. A 6-month prospective phenotypic and genotypic study performed at a single clinical microbiology laboratory assessed isolates growing in the MicroScan colistin well for concordance. While 37 of 39 isolates growing in the MicroScan colistin well displayed a colistin MIC of ≥4 by BMD, all were determined to be negative for the mcr-1 and mcr-2 genes by PCR. A retrospective review of all Escherichia coli, Klebsiella spp., and Enterobacter spp. tested by MicroScan at this laboratory in 2016 identified 260 of 7,894 (3.3%) isolates that grew in the MicroScan colistin well. Based on the data presented, clinical and public health laboratories could use the MicroScan colistin well as a first screen for the detection of isolates displaying elevated colistin MICs, which could then undergo further characterization.
More Related Videos
11:25Preparation of a Blood Culture Pellet for Rapid Bacterial Identification and Antibiotic Susceptibility Testing
Published on: October 15, 2014
09:26Antibiotic Efficacy Testing in an Ex vivo Model of Pseudomonas aeruginosa and Staphylococcus aureus Biofilms in the Cystic Fibrosis Lung
Published on: January 22, 2021
Related Concept Videos
Diffusion
Diffusion
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...