The Intra-Aortic Balloon Pump
Published on: February 5, 2021
Intra-aortic balloon pump postcardiac surgery: A literature review
Mansour Jannati1, Armin Attar2
1Department of Cardiovascular Surgery, Faghihi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran.
Abstract:
Intra-aortic balloon pump (IABP) has been the most commonly used mechanical assist circulatory device in many postcardiotomy low output disorders for decades. Mechanism of IABP is based on its inflation in time of the diastolic pressure in the aortic root resulting increase in the blood and oxygen amount of the coronary artery and its deflation in left ventricular afterload during the systolic period. Prophylactic and postoperative application of IABP has been suggested by researchers, which has been commonly used in high-risk patients undertaking coronary artery bypass grafting surgery or percutaneous coronary intervention. Other researchers put forward the idea of the percutaneous IABP insertion throughout the left axillary artery as a reliable and relatively well-tolerated approach and also as a recovery tool to bridge patients with end-stage heart failure to heart transplantation. The current review was aimed to give further insight into routine IABP application by presenting the basic principles and trends in the incidence, management, role of IABP recovery, and long-lasting mortality outcomes in patients with cardiovascular disorders and discussing previous and current evidence.
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...