Related Experiment Video
Updated: Jan 28, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Prognostic value of phase analysis on gated single photon emission computed tomography in patients with cardiac
Kazuhiro Koyanagawa1, Masanao Naya2, Tadao Aikawa1
1Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-15, Nishi-7, Kita-ku, Sapporo, 060-8638, Japan.
Background:
We aimed to determine the correlation between phase analysis, reflecting the heterogeneity of perfusion defects, and the dyssynchrony of the left ventricle wall motion, and adverse cardiac events in cardiac sarcoidosis (CS) patients.
Methods:
Fifty-seven consecutive patients with diagnosed CS (64 [IQR 55-71] years old, 14 males), who underwent 18F-FDG PET/CT and ECG-gated SPECT, were studied. FDG PET was analysed to measure cardiac metabolic volume (CMV), and total lesion glycolysis (TLG). The SPECT findings, such as LVEF, Summed Rest Score (SRS), bandwidth (BW) were evaluated.
Results:
The median of BW was 56° (IQR 40-95). BW showed a strong inverse correlation with LVEF (r = - 0.60, P < 0.0001), and positive correlation with SRS (r = 0.82, P < 0.0001). However, there were no significant correlations between BW and CMV or TLG. The Kaplan-Meier curves revealed a significantly higher rate of MACE in the high BW group (BW > 56°) than the low BW group (BW ≤ 56°) (15.1%/years vs. 4.4%/years, P = 0.025). In multivariable analysis, BW was a significant independent predictor of MACE (P = 0.015).
Conclusion:
Phase analysis on gated SPECT was a significant and independent predictor of MACE in patients with CS.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
05:16Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Imaging Studies III: Computed Tomography
Emission Spectra