Cardioembolic Sources in Patients With Small Single Subcortical Infarcts
Stela Celaj1, Shyam Prabhakaran2
1Department of Medicine, Northwestern University Feinberg School of Medicine.
Insights
Transthoracic echocardiogram (TTE) found cardiac abnormalities in nearly half of small single subcortical infarct (SSSI) patients. However, TTE findings altered antithrombotic management in only 5% of these ischemic stroke cases.
Area of Science:
- Cardiology
- Neurology
- Medical Imaging
Background:
- Transthoracic echocardiogram (TTE) is a standard diagnostic tool for ischemic stroke.
- The clinical utility of TTE in managing small single subcortical infarcts (SSSI) remains under-investigated.
Purpose of the Study:
- To determine the frequency of high- and medium-risk cardioembolic sources detected by TTE in SSSI patients.
- To assess whether TTE findings influenced the clinical management of SSSI.
Main Methods:
- Retrospective analysis of a prospective cohort of acute ischemic stroke patients.
- Brain MRI was used to identify SSSI (<1.5 cm lesions in specific brain regions).
- Patients with atrial fibrillation or >50% large artery stenosis were excluded.
Main Results:
- Of 908 patients, 75 (8.3%) had SSSI.
- TTE identified cardiac abnormalities in 46% of eligible SSSI patients.
- Common findings included dilated left atrium (29%) and patent foramen ovale (14%).
- Anticoagulants were prescribed in only 4.6% of patients based on TTE results.
Conclusions:
- TTE detects potential cardioembolic sources in a significant proportion of SSSI patients.
- However, TTE findings rarely alter antithrombotic management strategies in this specific patient group.
Abstract:
Transthoracic echocardiogram (TTE) is widely used as part of the work-up for ischemic stroke. However, the added utility of TTE in the management of small single subcortical infarcts (SSSI) has not been extensively evaluated. Therefore, we aimed to determine the frequency of high-risk and medium-risk cardioembolic sources diagnosed by TTE in SSSI patients, and whether the findings altered clinical management. We performed a retrospective analysis of a prospective cohort of patients with confirmed acute ischemic stroke enrolled in a single-center observational registry between August 2012 and July 2014. We assessed infarct topography on brain magnetic resonance imaging, blinded to final stroke subtype and treatment, to identify patients with SSSI. We defined SSSI as lesions in the corona radiata, basal ganglia, thalamus, or brainstem measuring <1.5 cm in maximal diameter. We excluded patients with atrial fibrillation and large artery stenosis >50%, and assessed the frequency of cardioembolic sources found by TTE in the remaining patients. Among 908 patients, 75 (8.3%) had SSSI, of which 4 (5.3%) had atrial fibrillation and 6 (8%) had symptomatic large artery stenosis. TTE revealed cardiac abnormalities in 46% of the remaining patients (mean age: 65.1 y, 52% female, 58% white). The most common findings were dilated left atrium (29%), patent foramen ovale (14%), and atrial septal aneurysm (7.7%). Anticoagulants were prescribed in 3 (4.6%) patients on the basis of TTE results. TTE identified potential cardioembolic sources in almost half of the patients, but altered antithrombotic management in only 5% of patients with SSSI.
More Related Videos
Related Concept Videos
Sinusoidal Sources
In homes, the power supplies use sinusoidal sources to provide electricity. These sources generate a voltage that varies sinusoidally...
AC Sources
Sources of Law
Constitutional law is foundational, deriving from federal and state constitutions, and...
Source Transformation
It is essential to note that when...
Multiple Voltage Sources
In series, the positive terminal of one battery is connected to the negative terminal of another battery. Hence, the voltage of each battery is added to give the net voltage, which is increased because each battery boosts the electrons that enter it. The same current flows through each battery because they are connected in series.
Batteries are...
Independent and Dependent Sources
Independent voltage or current sources supply a fixed amount of voltage or current, respectively, which is unaffected by other elements within the circuit. These are represented using specific symbols. Independent voltage sources are symbolized with polarities (+ and -), indicating the direction of the...