Background:
To evaluate the accuracy between actual outcomes and virtual surgical planning (VSP) in orthognathic surgery regarding the use of three-dimensional (3D) surface models for registration using iterative closest point (ICP) algorithm and generated color maps.
Material And Methods:
Construction of planning and postoperative 3D models in STL files format (M0 and M1, respectively) from CBCT of 25 subjects who had been submitted to bimaxillary orthognathic surgery was performed. M0 and M1 were sent to Geomagic software in semi-automatic alignment surface mesh order of M0 and M1 for registration using ICP algorithm to calculate mean deviation (MD, MD+, MD-, SD) and root mean square (RMS - 3D Error). Color maps were generated to assess qualitative congruence between M0 and M1. From deviation analysis, 3D Error was defined as accuracy measurement. To assess the reproducibility, the workflow was performed by two evaluators multiple times. t-tests were used to assess whether all means of MD, MD+, MD-, SD and 3D Error values would be ≤ - 2 mm and ≥ 2 mm.
Results:
High intra and inter evaluators correlation were found, supporting the reproducibility of the workflow. t-tests proved that all MDs and 3D Error values were > - 2 mm and < 2 mm.
Conclusions:
3D error mean was within the standards of clinical success lower than 2 mm. ICP algorithm provided a reproducible method of alignment between 3D models and generated color maps to evaluate 3D congruence but did not answer all methodological parameters regarding the assessment of accuracy in orthognathic surgery.
Related Concept Videos
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Color Vision
Accuracy and Precision