Report of a Coarctation of Aorta Stenting in an Infant
Mehdi Ghaderian1, Mohammad Reza Sabri1
1Pediatric Cardiology Research Center, Isfahan Cardiovascular Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran.
Insights
Coarctation of aorta (CoA) is a serious infant heart defect. This case study details successful stenting in a 3-month-old infant after balloon angioplasty failed, offering new hope for complex CoA cases.
Area of Science:
- Pediatric Cardiology
- Congenital Heart Disease
- Interventional Cardiology
Background:
- Coarctation of the aorta (CoA) is a congenital heart defect often leading to heart failure in infants.
- Current treatments include surgery and balloon angioplasty, but options for neonates are limited.
- Stent use in very young infants with CoA is not well-documented.
Observation:
- A 3-month-old infant presented with recurrent symptoms of CoA after initial balloon angioplasty.
- The infant's condition necessitated an alternative treatment approach.
- This case highlights a challenging clinical scenario in pediatric cardiology.
Findings:
- Successful stenting of the coarctation of the aorta was performed in the 3-month-old infant.
- The intervention addressed the recurrent obstruction effectively.
- This demonstrates the feasibility of stenting in select infant CoA cases.
Implications:
- Stenting may be a viable option for infants with recurrent CoA post-angioplasty.
- Further research is needed to establish the long-term safety and efficacy of stenting in neonates.
- This case expands treatment possibilities for complex congenital heart disease in young infants.
Abstract:
Coarctation of aorta (CoA) is a congenital heart disease that can lead to heart failure during infancy and neonatal period. Several treatments have been proposed for this disease, including surgery and balloon angioplasty. The experiences of using stents in small infants or neonatal patients are very low. In this article, we report a 3 months old age infant who after balloon angioplasty, his CoA symptoms had return and stenting of CoA was performed for him.
Related Concept Videos
The Aorta
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...
The Arch of Aorta
Encircling the heart, the coronary arteries form a ring-like structure before...
Thoracic Aorta
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...
Data Reporting and Recording
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process: