Liquid Drug Dosage Measurement Errors with Different Dosing Devices
Pradnya Joshi1, Sandeep B Bavdekar2
1Department of Pediatrics, TN Medical College and BYL Nair Charitable Hospital, Mumbai, India.
Insights
Parents frequently make medication dosing errors. Using a dosing syringe significantly improves accurate paracetamol syrup measurement in children compared to spoons or cups.
Area of Science:
- Pediatric pharmacology
- Medication safety
Background:
- Accurate medication dosing is crucial for pediatric patient safety.
- Parental medication administration errors are a significant concern.
- Various drug delivery devices exist, with differing accuracy levels.
Purpose of the Study:
- To quantify dosing errors in paracetamol syrup administration by parents.
- To identify the most preferred drug delivery device.
- To explore factors associated with accurate dosing.
Main Methods:
- Observational study involving 386 parents of children aged 6-60 months.
- Parents measured 5 ml paracetamol syrup using provided devices (spoon, syringe, cup).
- Dose accuracy was verified using a calibrated glass cylinder; errors exceeded 10% variation.
Main Results:
- 72 (18.65%) participants committed dosing errors (mild/moderate).
- Measuring cups were the most preferred device (69.95%).
- Syringe use was linked to significantly higher accuracy (3.57% error) versus spoons (56.25%) and cups (18.88%).
Conclusions:
- Drug delivery device type is the primary factor influencing accurate pediatric medication dosing.
- Dosing syringes offer superior accuracy compared to spoons and cups for paracetamol syrup.
- Interventions promoting syringe use could reduce pediatric dosing errors.
Abstract:
An observational study was carried out to determine the magnitude of dosing errors made by parents, the most-preferred drug delivery device and the association of age, gender, education of the caregiver and number of children with the proportion of accurate doses. After enrolment, parents of children aged 6-60 mo were instructed to measure 5 ml of syrup paracetamol using any of the devices (stainless steel spoon, disposable plastic syringe, dosing cup with etched markings) displayed. The quantum of measured dose was confirmed using a calibrated glass cylinder. Error was defined as over 10% variation around the prescribed dose. Of 386 participants, 72 (18.65%) committed error, with 58 (15.02%) and 14 (3.62%) committing mild and moderate errors, respectively. Measuring cup (270, 69.95%) was the commonest device chosen. Use of syringe was associated with greater accurate measurements (P < 0.05) with only 3 (3.57%) committing error compared to 18 (56.25%) and 51 (18.88%) committing error with spoon and cup, respectively. On multivariate analysis, device was the only factor significantly associated with accuracy in measurements.
Related Concept Videos
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Drug Dosage Regimen: Overview
Typically, the starting dose and dosing interval are guided by the manufacturer's recommendations based on clinical trials conducted during and after drug...
Drug Dosing: Infants and Children
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients