Evaluation with micro-CT of different anticoagulation strategies during hemodialysis in patients with
Floris Vanommeslaeghe1, Filip De Somer2, Iván Josipovic3
1Nephrology, Ghent University Hospital, Ghent, Belgium.
In patients with enhanced risk for bleeding, heparin-free hemodialysis (HD) with conventional dialyzers is routinely used. To explore the potential benefit of using heparin-coated dialyzers, we used a reference CT-scanning technique and registered different clotting parameters to quantify coagulation with heparin-coated versus non-coated dialyzers. Six HD patients with thrombocytopenia were dialyzed 240 min in a randomized crossover study with Evodial 1.3 or FX600 Cordiax, each without anticoagulation. Blood samples were taken from the vascular access predialysis, and from the dialyzer inlet and outlet at 5 and 240 min after dialysis start. Predialysis blood samples were analyzed for hemoglobin, hematocrit, thrombocytes, fibrinogen, and activated partial thromboplastin time. On dialyzer inlet and outlet blood samples, a viscoelastic measurement of blood coagulation was performed using a Sonoclot analyzer. After dialysis, dialyzers were visually scored, subsequently dried for 24 h, weighed, and scanned with micro-CT at a resolution of 25 µm. After image reconstruction, the open, non-coagulated fibers were counted in a representative cross-section at the dialyzer outlet. No sessions were terminated prematurely for circuit clotting. Heparin-coated dialyzers had more patent fibers on micro-CT versus non-coated dialyzers and also had a better score of subjective visual assessment of fiber clotting. There was no difference in subjective assessment of clotting at the venous drip chamber. With both dialyzers, all ACT values remained in the normal range, and were lower at the dialyzer outlet versus inlet. In conclusion, dialysis with a heparin-coated versus non heparin-coated membrane results in substantially less coagulated fibers during 4 h hemodialysis without systemic anticoagulation. Eventual leaching of heparin, immobilized on the fiber membrane, does not result in measurable systemic anticoagulation.
In patients with enhanced risk for bleeding, heparin-free hemodialysis (HD) with conventional dialyzers is routinely used. To explore the potential benefit of using heparin-coated dialyzers, we used a reference CT-scanning technique and registered different clotting parameters to quantify coagulation with heparin-coated versus non-coated dialyzers. Six HD patients with thrombocytopenia were dialyzed 240 min in a randomized crossover study with Evodial 1.3 or FX600 Cordiax, each without anticoagulation. Blood samples were taken from the vascular access predialysis, and from the dialyzer inlet and outlet at 5 and 240 min after dialysis start. Predialysis blood samples were analyzed for hemoglobin, hematocrit, thrombocytes, fibrinogen, and activated partial thromboplastin time. On dialyzer inlet and outlet blood samples, a viscoelastic measurement of blood coagulation was performed using a Sonoclot analyzer. After dialysis, dialyzers were visually scored, subsequently dried for 24 h, weighed, and scanned with micro-CT at a resolution of 25 µm. After image reconstruction, the open, non-coagulated fibers were counted in a representative cross-section at the dialyzer outlet. No sessions were terminated prematurely for circuit clotting. Heparin-coated dialyzers had more patent fibers on micro-CT versus non-coated dialyzers and also had a better score of subjective visual assessment of fiber clotting. There was no difference in subjective assessment of clotting at the venous drip chamber. With both dialyzers, all ACT values remained in the normal range, and were lower at the dialyzer outlet versus inlet. In conclusion, dialysis with a heparin-coated versus non heparin-coated membrane results in substantially less coagulated fibers during 4 h hemodialysis without systemic anticoagulation. Eventual leaching of heparin, immobilized on the fiber membrane, does not result in measurable systemic anticoagulation.
More Related Videos
Related Concept Videos
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Imaging Studies for Cardiovascular System V: CT
Hemodialysis I: Introduction