Related Experiment Video
Updated: Jan 28, 2026

06:42
Generation and Coherent Control of Pulsed Quantum Frequency Combs
Published on: June 8, 2018
9.6K
Unipolar subcycle pulse-driven nonresonant excitation of quantum systems
Optics Letters
|March 2, 2019
Abstract:
The interaction of subcycle pulses with quantum systems is considered when the pulse duration becomes much smaller than the timescales of electron oscillations. We show analytically that the interaction process in this case is governed by the electric pulse area. The efficient nonresonant excitation of quantum systems by subcycle pulses with a high degree of unipolarity is demonstrated. The results are confirmed by direct numerical solution of multilevel Bloch equations.
Related Concept Videos
Quantum Numbers
49.9K
It is said that the energy of an electron in an atom is quantized; that is, it can be equal only to certain specific values and can jump from one energy level to another but not transition smoothly or stay between these levels.
49.9K
The Quantum-Mechanical Model of an Atom
57.1K
Shortly after de Broglie published his ideas that the electron in a hydrogen atom could be better thought of as being a circular standing wave instead of a particle moving in quantized circular orbits, Erwin Schrödinger extended de Broglie’s work by deriving what is now known as the Schrödinger equation. When Schrödinger applied his equation to hydrogen-like atoms, he was able to reproduce Bohr’s expression for the energy and, thus, the Rydberg formula governing hydrogen spectra.
57.1K
Pulse
2.1K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
2.1K
Pulse
3.6K
The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
3.6K
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
1.8K
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
1.8K
Pulse Oximetry
1.4K
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.4K

