Constraints on Minute-Scale Transient Astrophysical Neutrino Sources

M G Aartsen1, M Ackermann2, J Adams1

  • 1Department of Physics and Astronomy, University of Canterbury, Private Bag 4800, Christchurch, New Zealand.

Related Concept Videos

Constraints and Statical Determinacy01:26

Constraints and Statical Determinacy

In structural engineering, the equilibrium of a system is not only determined by its equations of equilibrium but also with the help of constraints. Constraints refer to restrictions on the motion of a system. The proper combinations of constraints can minimize the total number of constraints needed to maintain a system in mechanical equilibrium. When this happens, the system is said to be statically determinate. For such systems, the unknown reaction supports can be estimated using equilibrium...
998
pH Scale02:41

pH Scale

Hydronium and hydroxide ions are present both in pure water and in all aqueous solutions, and their concentrations are inversely proportional as determined by the ion product of water (Kw). The concentrations of these ions in a solution are often critical determinants of the solution’s properties and the chemical behaviors of its other solutes. Two different solutions can differ in their hydronium or hydroxide ion concentrations by a million, billion, or even trillion times. A common means of...
79.5K
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
390
Scaling01:26

Scaling

In designing and analyzing filters, resonant circuits, or circuit analysis at large, working with standard element values like 1 ohm, 1 henry, or 1 farad can be convenient before scaling these values to more realistic figures. This approach is widely utilized by not employing realistic element values in numerous examples and problems; it simplifies mastering circuit analysis through convenient component values. The complexity of calculations is thereby reduced, with the understanding that...
593
Sinusoidal Sources01:18

Sinusoidal Sources

Direct current (DC) refers to an electric current that flows in a single direction, maintaining a constant polarity. This is in contrast to alternating current (AC), which periodically changes its direction and magnitude. AC forms the backbone of modern electricity transmission and distribution systems due to its efficient long-distance transmission capabilities.
In homes, the power supplies use sinusoidal sources to provide electricity. These sources generate a voltage that varies sinusoidally...
1.2K
Source Transformation01:15

Source Transformation

Source transformation is a fundamental technique employed in circuit analysis, offering a valuable tool for simplifying complex electrical circuits. This technique involves the replacement of either a voltage source in series with a resistor by a current source in parallel with a resistor, or vice versa. The key concept here is that when the original sources are deactivated (turned off), the equivalent resistance at the circuit's end terminals remains the same.
It is essential to note that when...
11.4K