Determining the cut-off value of the APTT mixing test for factor VIII inhibitor: reply
1Protein Technology, Engineering 1, Sysmex Corporation, Kobe, Hyogo, Japan.
Clinical Chemistry and Laboratory Medicine
|March 2, 2019
Abstract
No abstract available in PubMed .
Keywords:
acquired hemophiliaactivated partial thromboplastin timefactor VIII inhibitorlupus anticoagulantmixing testMore Related Videos
07:44Determining the Chemical Composition of Corrosion Inhibitor/Metal Interfaces with XPS: Minimizing Post Immersion Oxidation
Published on: March 15, 2017
16.2K
10:28A Semi-High-Throughput Adaptation of the NADH-Coupled ATPase Assay for Screening Small Molecule Inhibitors
Published on: August 17, 2019
10.4K
Related Concept Videos
Eukaryotic Transcription Inhibitors
11.0K
Certain biochemical processes, such as embryonic development and cell growth regulation, depend on the repression of specific genes. DNA binding proteins known as eukaryotic transcription inhibitors regulate the repression of gene expression in eukaryotes. The presence of these inhibitors at the required location and time in the cell is triggered by the presence of hormones and additional signals from other cells.
Eukaryotic transcription inhibitors usually contain two distinct domains, a...
Eukaryotic transcription inhibitors usually contain two distinct domains, a...
11.0K
Transcription Factors
82.7K
Tissue-specific transcription factors contribute to diverse cellular functions in mammals. For example, the gene for beta globin, a major component of hemoglobin, is present in all cells of the body. However, it is only expressed in red blood cells because the transcription factors that can bind to the promoter sequences of the beta globin gene are only expressed in these cells. Tissue-specific transcription factors also ensure that mutations in these factors may impair only the function of...
82.7K
Cut-off Frequency of BJT
1.4K
Cut-off frequencies in Bipolar Junction Transistors (BJTs) mark the transition between the signal's pass band and stop band, influencing their performance in amplifying or attenuating frequencies. These frequencies are crucial for designing BJTs to meet specific operational requirements in electronic circuits.
Alpha Cut-Off Frequency: Pertinent to the common-base configuration, the alpha cut-off frequency defines the upper-frequency limit at which the current gain, alpha, remains stable. As...
Alpha Cut-Off Frequency: Pertinent to the common-base configuration, the alpha cut-off frequency defines the upper-frequency limit at which the current gain, alpha, remains stable. As...
1.4K
Brick Cutting Techniques
632
Brick-cutting techniques involve various tools and methods to shape bricks for construction. A mason's hammer with a chisel-pointed end is used for basic shaping through sharp, precise strikes. For more complex shapes requiring higher precision, a power saw with a water-cooled diamond blade is used.
Cut bricks are categorized by size. Bricks cut to half their original length are called half-bats, while those cut to three-fourths their length are known as three-fourth bats.
Special types of...
Cut bricks are categorized by size. Bricks cut to half their original length are called half-bats, while those cut to three-fourths their length are known as three-fourth bats.
Special types of...
632
Mixing Concrete
381
Concrete mixing ensures a homogenous blend where aggregates are well-coated with cement paste. Concrete mixing is typically done using two main types of mixers: batch and continuous. Batch mixers handle one batch at a time, thoroughly combining materials before discharging and receiving the next batch. In contrast, continuous mixers receive a steady flow of ingredients, mixing them consistently and discharging without interruption. Within batch mixers, tilting drum mixers mix with internal...
381
Mixing Time
475
The concept of mixing time is significant in producing a uniform concrete mix with the required strength. The mixing period starts once all components are in the mixer. Initially, the mixer is charged with 10% of the water, followed by the consistent addition of solids and then 80% of the water. The remaining water is added later, within the first quarter of the mixing period. The minimum mixing time varies according to the mixer's capacity; for example, mixers with up to 1 cubic yard...
475