Related Experiment Video
Updated: Jan 28, 2026

High Density Event-related Potential Data Acquisition in Cognitive Neuroscience
Published on: April 16, 2010
Event-by-event non-rigid data-driven PET respiratory motion correction methods: comparison of principal component
Silin Ren1,2,3, Yihuan Lu4, Ottavia Bertolli5
1Department of Biomedical Engineering, Yale University, New Haven, CT, United States of America.
Abstract:
Respiratory motion is a major cause of degradation of PET image quality. Respiratory gating and motion correction can be performed to reduce the effects of respiratory motion; these methods require motion information, typically obtained from external tracking systems. Various groups have studied data-driven (DD) motion estimation methods. Recently, a DD respiratory motion estimation method was established by calculating the centroid of distribution (COD) of listmode events, which was then used with event-by-event respiratory motion correction (EBE-MC) and showed results comparable to those with an external motion tracking device. The EBE-MC method only corrected for rigid motion, so that non-rigid components still contributed to motion-induced blurring. A non-rigid respiratory motion correction (NRMC) was later developed to overcome this problem, but was only evaluated using signals from an external monitor. Thus, it is desirable to further develop DD motion estimation to achieve the best respiratory motion correction results. We evaluated two DD respiratory motion detection methods, COD and principal component analysis (PCA), by comparing the extracted motion trace to that acquired by the Anzai system in dynamic studies with two tracers. PCA was chosen as a preliminary study indicated that it produced stable results than other DD methods. We then developed and performed DD-EBE-NRMC using either COD- or PCA-derived respiratory motion information. DD correction results were compared with Anzai-based results. For all tested studies, both COD and PCA showed a good-to-excellent match with Anzai signals, with PCA showing a higher correlation with Anzai signals. The DD-EBE-NRMC results showed that both COD and PCA provide comparable image quality improvement to the Anzai-based correction. Although COD showed a lower correlation with Anzai than PCA, COD-based NRMC results are comparable to those of PCA, both of which showed great reduction in motion-induced blurring.
Related Concept Videos
Integration of Synaptic Events
Equation of Motion for a Rigid Body
The combined moments generated about the center of mass of the object are equal to the rate of change of the angular momentum of the body. An external force, when applied at a different...
Planar Rigid-Body Motion
Planar motion is typically divided into three distinct categories. The first is rectilinear translation, demonstrated by a subway train that moves along...
Schwarzschild Radius and Event Horizon
The minimum speed required to launch a projectile from the surface of an object to which it is gravitationally bound so that it eventually escapes the object’s gravitational field is called the escape velocity. The escape velocity is independent of the mass of the object. Merging the idea of escape...
Curvilinear Motion: Rectangular Components
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
Curvilinear Motion: Normal and Tangential Components
The positive direction of the t-axis aligns with the increasing position of the car along the curved path, denoted by the unit vector ut. Simultaneously, the n-axis, perpendicular to the t-axis, dissects the curved path into differential arc segments, each forming the arc of a circle with a radius of...

