Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Knee Joint01:23

Knee Joint

3.2K
The knee joint is the most complicated joint in the body. It consists of three articulations– two tibiofemoral and one patellofemoral. As is characteristic of synovial joints, the knee joint has a thin articular capsule that partially surrounds this joint cavity. Additionally, several ligaments, muscles, and cartilaginous structures support the movement of the knee.
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
3.2K
Total Voids in Concrete01:12

Total Voids in Concrete

480
Total voids in concrete encompass gel water volume, capillary pores, and entrapped air. Gel water (retained within the cement hydration products) and physically entrapped or adsorbed water are significant for the hydration process. For complete hydration, it's estimated that the space needed for the products of a cubic centimeter of cement doubles. Capillary pores constitute the unoccupied space within the hydrated cement paste, with their size largely influenced by the water-to-cement...
480
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

13.4K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
13.4K
Static, Stagnation, Dynamic and Total Pressure01:24

Static, Stagnation, Dynamic and Total Pressure

1.5K
The concept of static, stagnation, dynamic, and total pressure is fundamental in fluid dynamics, often explained using Bernoulli's equation:
1.5K
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview01:13

Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview

1.2K
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
1.2K
The Extracellular Matrix01:42

The Extracellular Matrix

88.8K
Overview
88.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Longitudinal wastewater-based surveillance of vancomycin-resistant Enterococci in tertiary-care hospitals.

The Science of the total environment·2026
Same author

Fully Hydroxyapatite-Coated, Collared, Triple-Taper Stems May Be Safe for all Patients Undergoing Primary Total Hip Arthroplasty: Minimum Two-Year Follow-Up.

The Journal of arthroplasty·2026
Same author

Direct visualization-guided PENG block (Pericapsular nerve Group): optimizing postoperative analgesia in total hip arthroplasty.

Journal of orthopaedic surgery and research·2026
Same author

Glycated Albumin as a Predictor of Adverse Outcomes in Patients Undergoing Primary Total Hip and Knee Arthroplasty: A Multicenter Prospective Study.

The Journal of arthroplasty·2025
Same author

When Is It Safe for Patients to Air Travel After Total Hip and Knee Arthroplasty: A Comprehensive Review.

JBJS reviews·2025
Same author

<i>Vitis vinifera</i> L. Leaves as a Source of Phenolic Compounds with Anti-Inflammatory and Antioxidant Potential.

Antioxidants (Basel, Switzerland)·2025
Same journal

Early Quadriceps Recovery and Edema Reduction Predict Functional Performance After Total Knee Arthroplasty.

The journal of knee surgery·2026
Same journal

Lateral Extra-articular Tenodesis Was Not Associated With Improved Mid-term Outcomes After Primary BPTB ACL Reconstruction in Amateur Soccer Players: A Prospective Comparative Cohort Study.

The journal of knee surgery·2026
Same journal

Management of Distal Femoral Periprosthetic Fractures after Total Knee Arthroplasty: Fixation versus Revision Reconstruction.

The journal of knee surgery·2026
Same journal

Factors affecting Union Rates following Fixation of Osteochondritis Dissecans of the Knees: A Systematic Review and Meta-Analysis.

The journal of knee surgery·2026
Same journal

Age and Racial Disparities in Manipulation Rates Following Total Knee Arthroplasty: An 11-Year Review.

The journal of knee surgery·2026
Same journal

When Is Distal Femoral Replacement Indicated? Insights From Periprosthetic and Native Distal Femoral Fractures Around the Knee.

The journal of knee surgery·2026
See all related articles

Related Experiment Video

Updated: Jan 28, 2026

Reverse Total Shoulder Arthroplasty
10:10

Reverse Total Shoulder Arthroplasty

Published on: July 5, 2011

43.9K

Robotics in Total Knee Arthroplasty.

Maria Bautista1, Jorge Manrique2,3, William J Hozack2

  • 1Department of Orthopedics and Traumatology, Hospital Universitario Fundación Santa Fe de Bogotá, School of Medicine, Universidad del Rosario, Bogota, Colombia.

The Journal of Knee Surgery
|March 2, 2019
PubMed
Summary
This summary is machine-generated.

Robotic total knee arthroplasty (TKA) offers potential for improved patient satisfaction but lacks definitive proof of enhanced outcomes. Current evidence suggests robotic TKA does not increase surgical time or complications.

More Related Videos

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
09:31

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty

Published on: February 27, 2018

12.4K
In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
07:33

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty

Published on: May 5, 2023

1.1K

Related Experiment Videos

Last Updated: Jan 28, 2026

Reverse Total Shoulder Arthroplasty
10:10

Reverse Total Shoulder Arthroplasty

Published on: July 5, 2011

43.9K
Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
09:31

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty

Published on: February 27, 2018

12.4K
In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
07:33

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty

Published on: May 5, 2023

1.1K

Area of Science:

  • Orthopedic surgery
  • Robotics in medicine
  • Arthroplasty

Background:

  • Total knee arthroplasty (TKA) significantly enhances patient quality of life.
  • A notable percentage of TKA patients report dissatisfaction with surgical outcomes.
  • Robotic-assisted TKA is emerging as a technology to potentially improve patient satisfaction.

Purpose of the Study:

  • To objectively assess the current evidence for robotic technology in TKA.
  • To evaluate the role of robotics in improving patient satisfaction and clinical results.
  • To review the advantages and disadvantages of available robotic TKA systems.

Main Methods:

  • Review of current literature on robotic-assisted total knee arthroplasty.
  • Analysis of evidence regarding surgical precision, kinematics, and soft tissue balance.
  • Examination of data on implant survival, function, and patient-reported outcomes.

Main Results:

  • Robotic TKA systems aim for precise bone cuts and intraoperative feedback.
  • Evidence for improved implant survival, function, and patient outcomes with robotics is still accumulating.
  • Robotic TKA is not currently associated with increased surgical time or complications.

Conclusions:

  • Robotic technology in TKA shows promise for enhancing surgical accuracy and patient satisfaction.
  • Further research is needed to conclusively demonstrate superior long-term outcomes compared to conventional TKA.
  • Robotic TKA appears safe in terms of surgical duration and complication rates.