Measuring Sterilizing Values In Containers of Food Using Thermocouples and Biological Indicator Units 1, 2
I J Pflug1, G Smith1, R Holcomb1
1Department of Food Science and Nutrition, University of Minnesota, St. Paul, Minnesota 55108 and the Green Giant Company, Le Sueur, Minnesota.
Physical and biological methods for measuring sterilization values (F0) in canned peas showed good agreement. Physical measurements slightly overestimated sterilization, indicating reliable process validation for food safety.
Area of Science:
- Food Science
- Microbiology
- Process Engineering
Background:
- Accurate measurement of sterilization value (F0) is crucial for ensuring food safety and product quality in canned goods.
- Traditional physical methods rely on heat penetration data, while biological indicator units (BIUs) offer a direct measure of microbial inactivation.
Purpose of the Study:
- To compare the accuracy and variability of sterilization values (F0) determined by physical (PHY) heat penetration data versus biological indicator units (BIUs).
- To assess the reproducibility of physical heat penetration measurements within experimental series.
Main Methods:
- Conducted three experimental series, each with multiple tests using thermocouples (for physical data) and BIUs in cans of peas in brine.
- Calculated sterilization values (F0) from both heat penetration data and BIU results.
- Analyzed test-to-test reproducibility for physical data.
Main Results:
- The mean difference between physical and biological sterilization values was +1.2 minutes (F0 (PHY) - F0 (BIO)).
- Physical measurements showed lower variability (coefficient of variation = 0.03) compared to biological measurements (coefficient of variation = 0.06).
Conclusions:
- Physical heat penetration data provide a reliable and less variable method for determining sterilization values in canned peas.
- The slight overestimation by physical methods suggests a conservative approach to process validation, ensuring adequate microbial inactivation.
Related Concept Videos
Measurement: Standard Units
Measurement: Derived Units
Units of Measurement
There are various well-known historical measurement systems, such as the Babylonian system, the Roman system, the Egyptian system, the Olympian system, the British system, and the Indus...
Indicators
Units and Standards of Measurement
Measurements of physical quantities are...
Predicting Products: SN1 vs. SN2
With increased substitution on the alkyl halide,...