Related Experiment Video
Updated: Jan 28, 2026

Exfoliation of Egyptian Blue and Han Blue, Two Alkali Earth Copper Silicate-based Pigments
Published on: April 24, 2014
Six-Month Color Stability Assessment of Two Calcium Silicate-Based Cements Used in Regenerative Endodontic Procedures
Paulo J Palma1, Joana A Marques2, Rui I Falacho3
1Institute of Endodontics, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal. ppalma@uc.pt.
Aim:
The purpose of the present study is to assess the color stability of two calcium silicate-based cements (CSCs) used in regenerative endodontic procedures (REPs).
Methods:
A total of 40 acrylic single-rooted transparent teeth, with immature apex, were used. Root canals were filled up to 3 mm below the level of the cementoenamel junction, with either saline solution (Mineral Trioxide Aggregate (MTA)/saline and Biodentine/saline) or blood (MTA/blood and Biodentine/blood). Subsequently, ProRoot MTA® or BiodentineTM was placed in the root canal to create a cervical barrier. Color measurement was carried out at four different evaluation periods (3 h, 72 h, 7 days, and 6 months). Shade analysis within the L* a* b* color space was performed and color variation (∆E) calculated. The significance level for statistical analysis was set at p < 0.05.
Results:
The four groups showed a significant decrease in L* values over time. The ΔE value increased over time for all groups but was not statistically significant for the Biodentine/blood group. Two-way ANOVA showed no interaction between the CSC and treatment (contact with saline solution or blood). CSC used was the factor responsible for ΔE over time, inducing statistically significant color variations from T3H to T7D (p = 0.04) and T3H to T6M (p < 0.01). After 6 months, MTA/saline had 5.08 (p = 0.001) higher ΔE than Biodentine/Saline and the MTA/blood had 3.65 (p = 0.009) higher than Biodentine/blood.
Conclusions:
After 6 months, regardless of blood exposure, Biodentine exhibits superior color stability compared to MTA. Biodentine might be a suitable alternative to MTA as a cervical barrier material in REPs.
More Related Videos
Related Concept Videos
Hydration of Cement
Soundness of Cement
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Portland Cement
Fineness of Cement
Direct...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...