Related Experiment Video
Updated: Jan 28, 2026

Application of Optical Coherence Tomography to a Mouse Model of Retinopathy
Published on: January 12, 2022
Early Visualization of Optic Canal for Safe Anterior Clinoidectomy: Operative Technique and Supporting Computed
Toshikazu Kimura1, Akio Morita2
1Department of Neurosurgery, Japanese Red Cross Medical Center, Shibuya-ku, Tokyo, Japan.
Background:
Anterior clinoidectomy is considered difficult because important structures are adjacent to but hidden behind the anterior clinoid process (ACP). We sought to make anterior clinoidectomy a simpler procedure.
Methods:
A modification of anterior clinoidectomy is presented. To obtain a radiologic basis, original images from 357 consecutive sets of computed tomography angiography data were assessed.
Results:
Anterior clinoidectomy was performed in 77 consecutive patients, as follows. By making a small window in the lateral wall of the ACP and curetting out the content inside, the lateral wall of the optic canal was easily exposed and functioned as a landmark for removal of the remaining bone. In addition, by removing the posterior edge and thinning the lateral part, the ACP was fractured and removed. The optic canal was opened if needed. No complications due to anterior clinoidectomy were observed. Among the 689 sides evaluated, 641 sides showed cancellous bone and 29 showed well-developed pneumatization inside the ACP. In each ACP examined, we observed the presence of compact bone facing the optic nerve, which constitutes the lateral wall of the optic canal. On 180 sides, part of the compact bone between the clinoid process and the internal carotid artery was absent; in other cases, thin compact bone was present.
Conclusions:
Visualizing the optic canal in the early stage of the procedure allows anterior clinoidectomy to be performed safely.
More Related Videos
13:10Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
11:49Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Finding the Center of Gravity
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection