Related Experiment Video
Updated: Jan 28, 2026

On the Preparation and Testing of Fuel Cell Catalysts Using the Thin Film Rotating Disk Electrode Method
Published on: March 16, 2018
Dissolution testing of oral film preparations: Experimental comparison of compendial and non-compendial methods
Isabell Speer1, Maren Preis2, Jörg Breitkreutz1
1Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University, Universitaetsstr. 1, 40225 Duesseldorf, Germany.
Abstract:
In vitro dissolution testing is one of the most frequently used tests in pharmaceutical quality control, since evaluation of the drug release profile and estimation of the dosage form performance is enabled. However, for oral film preparations no standardized compendial dissolution method or specifications are available worldwide. Therefore, four different dissolution methods described in the literature, namely the basket method, the paddle and glass disc (PGD) method, the flow-through cell with adapted film sample holders produced via 3D printing (FTC + FH3D) and the "Punch and Filter" (PAF) method were chosen and their suitability to investigate oral films with different release properties was compared. For this purpose, oral films with immediate (ODFIR) and prolonged theophylline release (ODFPR) as well as double layer films (ODFDL) were produced and investigated. All produced ODFs disintegrated rapidly in 27-46 s and showed content uniformity with acceptance values between 7.3 and 11.3%. The FTC + FH3D and the PGD method showed increased discriminatory power and were suitable to investigate the integrity of the shielding layer of ODFDL as shown by linear prolonged release (mean dissolution time at 80% drug release (MDT80) of 366.8 and 217.1 min for FTC + FH3D and PGD method), which was not possible applying the basket and PAF method. These methods did not allow clear discrimination between ODFIR and ODFDL, since immediate release profiles with MDT80 values of 4.1 and 11.0 min for the basket method and 6.8 and 15.5 min for the PAF method were found for both, ODFIR and ODFDL respectively. The FTC + FH3D method provided high flexibility, which may be used to simulate gastrointestinal transit. The PAF method reflects physiological conditions of the oral cavity and enables mimicking the in vivo film application. These methods are particularly valuable for research and development purposes. Due to the simple and well standardized instrumental setup as well as high robustness, the basket and PGD method are particularly suitable for use in pharmaceutical quality control.
Related Concept Videos
In Vitro Drug Dissolution: Compendial Testing Models I
In Vitro Drug Dissolution: Compendial Testing Models II
Drug Dissolution: Requirements and Profile Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
In Vitro Drug Dissolution: Alternative Methods
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...

