Related Experiment Video
Updated: Jan 28, 2026

Author Spotlight: Validating Cancer Therapy Responses with Desmoplastic Spheroid Models
Published on: September 27, 2024
Non-invasive massive growing prostheses reduce infection in paediatric cancer patients
Melanie Jean Coathup1, Samee Ahmad1, Julian F Maempel2
11 Institute of Orthopaedics and Musculoskeletal Science, Division of Surgery and Interventional Science, University College London, The Royal National Orthopaedic Hospital, Middlesex, UK.
Purpose:
In this study, we asked the question of whether non-invasive (NI) extendible bone tumour implants are as reliable and reduce infection when compared with patients who received a minimally invasive (MI) extendible implant.
Methods:
Forty-two NI extendible bone tumour implants were investigated at a mean follow-up of 22 months (range, 1-87 months) and 63 MI implants at a mean follow-up of 49 months (range, 1-156 months).
Results:
Kaplan-Meier analysis showed that the probability of MI implant survival was 58.8% compared with 78.6% in NI patients. No significant difference between these two patient groups was found. Infection was the main reason for failure in the MI implant group where nine (35%) implants were revised. However, only one (11%) NI implant was revised for infection ( p = 0.042). None of the NI implants failed due to aseptic loosening; however, six (23%) MI implants were revised for aseptic loosening of the intramedullary stem. Four (15%) of the failed MI implants were revised due to full extension and five (56%) of failed NI implants were replaced as the implant had been fully extended where the patient still required growth.
Conclusion:
Where possible, an NI massive prosthesis should be used in this patient group. Our results suggest that MI prostheses should be infrequently used due to the high incidence of infection. Lengthening of NI prostheses is painless, can be carried out in the clinic and is more cost-effective. However, further work is required to increase the amount of growth potential available in these implants.
Related Concept Videos
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Methods of reducing fever
Pharmacological Methods of Reducing Fever:
Adaptations that Reduce Water Loss
Role of Reduced Coenzymes NADH and FADH₂
Redox Titration: Other Oxidizing and Reducing Agents
Reduced Mass Coordinates: Isolated Two-body Problem

