Background:
The desire of pediatric surgeon to reduce incision related morbidity and pain while achieving good cosmetic results has recently led to the introduction of single incision pediatric endosurgery [SIPES] and needlescopic surgery. Intracorporeal suturing and knot tying during SIPES remain challenging. The aim of this study is to introduce a novel and simple technique for intracorporeal suturing of the pediatric inguinal hernia after needlescopic disconnection of hernia sac using just needles rather than laparoscopic instruments. It is an imitation of the principles of sewing machine.
Methods:
The first author discussed the idea of the technique with the coauthors and a demonstration was done on a Silicon Pad before application of the technique on children with congenital inguinal hernia [CIH] for peritoneum closure after needlescopic disconnection of the hernia sac. The main outcome measures were feasibility of the technique, suturing and knotting time and recurrence rate.
Results:
The sutures were snugly applied to the ridges of Silicon Pad with good approximation and the knot was firmly tightened in all experiments. After applying and mastering the technique on a Silicon Pad, we shifted to use it on 373 children with 491 hernia defects. All operations were completed by the needlescopic technique without the need for insertion of any laparoscopic instruments. The time required for suturing of the peritoneum around internal inguinal ring [IIR] and knot tying, decreased considerably from 6 min 27 s in the first operation to less than 4 min after the fifth operation and stabilized at approximately 4 min 30 s. No major intraoperative complication. There was no recurrence during a mean follow-up period of 19.6 ± 1.2 months.
Conclusion:
The closure of the peritoneum around the IIR using needles mimicking what is happening in sewing machine suturing is a feasible, safe and effective line of treatment of children with CIH. The cosmetic results are 42 outstanding without any recurrence.
More Related Videos
Related Concept Videos
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Bernoulli's Principle: Applications
Entrainment devices use a high fluid speed to create low pressures and, thus, entrain one fluid into another. Some examples of these devices are given below:
Design Example: Application of Archimedes' Principle
The volume of seawater displaced by the block is determined by first calculating the block's weight. This is done by multiplying the...
The Uncertainty Principle
Hardy-Weinberg Principle
The Pauli Exclusion Principle