Snap-valve cerebral shunt design for intracranial pressure operation and ultrasound visualization
S C Mitchell1, G Grangard1, W Kahouli1
1Dartmouth College, United States.
Abstract:
Cerebral spinal fluid (CSF) shunts are the main treatment for hydrocephalus. They divert excess CSF from the ventricular system to the abdominal, pleural, or intravascular space where it is absorbed. The shunt valve regulates flow based on intracranial pressure (ICP) to maintain a physiologically stable and safe ICP. Shunt malfunction is difficult to detect, life-threatening and common. The present study demonstrates that snap-though buckling (STB) shells can be transformed into pressure-relief valves that act in the normal physiological range of ICP. Three different shell designs in this preliminary experiment were found to have opening and closing pressures that fall within the physiologically normal range of ICP of 6 to 25 cm H2O. Furthermore, these STB shells demonstrate a valve actuation that is visible by ultrasound and have an implantable form-factor that is similar to currently available shunt valves. The unique characteristics of STB shell valves have potential clinical applications for shunt monitoring using ultrasound imaging and can be fabricated from antibiotic-impregnated materials to mitigate shunt infection. These characteristics make STB valves attractive for future use in cerebral shunt systems.
More Related Videos
10:41Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021
09:00The Rabbit Blood-shunt Model for the Study of Acute and Late Sequelae of Subarachnoid Hemorrhage: Technical Aspects
Published on: October 2, 2014
Related Concept Videos
Shunt Admittances
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Factorial Design
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Group Design
Operational Amplifiers