Related Experiment Video
Updated: Jan 28, 2026

A Novel Approach for the Administration of Medications and Fluids in Emergency Scenarios and Settings
Published on: November 9, 2016
High-alert medication administration and intravenous smart pumps: A descriptive analysis of clinical practice
Kathryn K Marwitz1, Karen K Giuliano2, Wan-Ting Su3
1Purdue University College of Pharmacy, 575 Stadium Mall Drive, West Lafayette, IN, 47907, USA.
Background:
The Institute for Safe Medication Practices (ISMP) describes high alert medications (HAM) as medications that represent a heightened risk of patient harm when used in error. IV smart pumps with dose error reduction systems (DERS) were created to help address medication administration errors. Compliance with DERS provides a measure of how accurately a hospital uses smart pump technology to reduce IV medication error.
Objective:
The primary purpose of this research was to use the REMEDI dataset, an aggregate, multi-hospital database inclusive of smart pump analytics, to improve the current understanding of clinical practices for IV HAM administration.
Methods:
Descriptive analyses and analysis of variance (ANOVA) were used to test for differences in the mean DERS alert override rate, and mean DERS alert override to reprogram ratio between non-HAM and HAM overall, by hospital system, and by pump type.
Results:
High mean override rates for non-HAM (73.8%) and HAM (75.8%) and high override to reprogram ratios for both non-HAM (7.30) and HAM (9.92) were seen. No significant differences were found in override rates (p = 0.23) and override to reprogram ratios (p = 0.06) between non-HAM and HAM. By hospital system, significant variability in override rates and override to reprogram ratios were seen. By pump type, there were no significant differences in the mean override rates (Baxter: p = 0.09; BD p = 0.34; ICU Medical p = 0.18) and the mean override to reprogram ratios (Baxter p = 0.84; BD p = 0.03; ICU Medical p = 0.63) between non-HAM and HAM.
Conclusions:
These findings indicate that the majority of alerts generated are bypassed by clinicians at the point of care, a symptom of alert fatigue. Given the potential for significant patient harm with HAM and the high DERS alert override rates that routinely occur during IV medication administration, this study provides further support for clinician-driven IV smart pump innovation to improve alert fatigue.
More Related Videos
05:40The Motivation for Alcohol Reward: Predictors of Progressive-Ratio Intravenous Alcohol Self-Administration in Humans
Published on: April 28, 2022
09:16A General Method for Evaluating Deep Brain Stimulation Effects on Intravenous Methamphetamine Self-Administration
Published on: January 22, 2016
Related Concept Videos
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pleural Disorders: Types and Brief Description
Eulerian and Lagrangian Flow Descriptions
The Eulerian method focuses on fixed points in space where fluid properties, such as velocity, pressure, and temperature, are observed as the fluid moves between these...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...