A systematic review of epinephrine stability and sterility with storage in a syringe
Hannah G Parish1, Jacquelyn R Morton1, Julie C Brown1,2
11Seattle Children's Hospital, 4800 Sandpoint Way NE, Seattle, WA 98105 USA.
Background:
Epinephrine is a lifesaving medication in the treatment of anaphylaxis. Epinephrine auto-injectors are the preferred method of epinephrine administration, but are not universally available or affordable. Little is known about the effects on epinephrine when it is drawn up in advance and stored as prefilled syringes.
Objective:
To study the stability and sterility of epinephrine when stored in syringes.
Methods:
We searched Embase, Medline, and Web of Science in June 2016 for all studies of epinephrine stored in syringes in concentrations between 0.1 and 1 mg/mL that measured epinephrine stability and/or sterility over time, regardless of date published or language.
Results:
Three studies were included, one testing two concentrations of epinephrine. Only one study tested epinephrine 1 mg/mL, the concentration clinically relevant for intramuscular use during anaphylaxis. Neither this study nor the one study testing 0.7 mg/mL epinephrine found significant degradation after 56 and 90 days, respectively. One of the two studies testing epinephrine at a concentration of 0.1 mg/mL found significant degradation by 14 days; the other found no degradation up to 168 days. Two studies tested for bacterial growth, with none detected after 28 and 90 days, respectively. One study tested for fungal growth, with none detected after 90 days.
Conclusions:
Limited evidence suggests that syringes filled with 1 mg/mL epinephrine are stable and sterile for 90 days. More research is needed testing the duration of stability and sterility of prefilled syringes with the 1 mg/mL concentration most commonly used in anaphylaxis, testing more extensively in different storage conditions and across a wider range of marketed syringe brands.
Related Concept Videos
Storage
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Nuclear Stability
To hold positively charged protons together...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
RNA Stability