Optic Nerve Sheath Point of Care Ultrasound: Image Acquisition
Published on: August 18, 2023
High-fidelity Training Model for Measurement of Dynamic Optic Nerve Sheath Diameter Using Transorbital
Zakir Hajat1, Michael Dinsmore, Lashmi Venkatraghavan
1Department of Anesthesia, Toronto Western Hospital, University Health Network, University of Toronto, Toronto, ON, Canada.
Background:
Transorbital ultrasonographic measurement of optic nerve sheath diameter (ONSD) is an important technique for bedside assessment of raised intracranial pressure (ICP). However, developing competency for this clinical skill requires practice scans on both normal subjects and patients with raised ICP. The aim of this study is to develop a high-fidelity training model capable of measuring dynamic changes in ONSD and to test the reliability and reproducibility of the model at different simulated ICP values.
Materials And Methods:
We designed and developed a high-fidelity training model for dynamic ONSD measurement using a hemispherical table tennis ball, mounted on a 3.0-mm pediatric microcuffed endotracheal tube (ETT). Two independent investigators then performed a randomized blinded study to assess the reliability and reproducibility of the model. A total of 30 ONSD measurements (10 measurements each for 3 ETT cuff volumes of 0.1, 0.2, and 0.3 mL, simulating an ONSD of a normal, borderline, and raised ICP, respectively) were performed by each investigator. Intraclass correlation coefficients and Bland-Altman plots were calculated to analyze the level of agreement between the investigators.
Results:
Our model was able to provide dynamic changes in ONSD secondary to ETT cuff volume changes. Small increments of 0.1 mL cuff volume changes produced immediate changes in ONSD that are similar to those observed in patients. The median interobserver difference in ONSD was 0.3 mm (interquartile range, 0. to 0.4 mm). Intraclass correlation coefficient was 0.89, 0.89, and 0.90 for 0.1, 0.2, and 0.3 mL ETT cuff volumes, respectively.
Conclusions:
We have developed a clinically relevant model capable of simulating changes in ONSD in patients with normal and raised ICP. This model could be a valuable training tool to gain scanning experience in optic nerve ultrasonography, and improve operators' technical abilities.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies II: Ultrasonography
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Dynamic Equilibrium
Nerve Supply of the GI Tract
The enteric nervous system consists of two major plexuses: the myenteric plexus (Auerbach's plexus) and the submucosal plexus (Meissner's plexus). These plexuses are located within the layers of...