Pedicle Screw Placement Using an Augmented Reality Head-Mounted Display in a Porcine Model
Published on: May 24, 2024
Augmented and Virtual Reality Instrument Tracking for Minimally Invasive Spine Surgery: A Feasibility and Accuracy
Gustav Burström1,2, Rami Nachabe3, Oscar Persson1,2
1Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
Study Design:
Cadaveric animal laboratory study.
Objective:
To evaluate the feasibility and accuracy of pedicle cannulation using an augmented reality surgical navigation (ARSN) system with automatic instrument tracking, yielding feedback of instrument position in relation to deep anatomy.
Summary Of Background Data:
Minimally invasive spine surgery (MISS) has the possibility of reducing surgical exposure resulting in shorter hospital stays, lower blood loss and infection rates compared with open surgery but the drawback of limiting visual feedback to the surgeon regarding deep anatomy. MISS is mainly performed using image-guided 2D fluoroscopy, thus exposing the staff to ionizing radiation.
Methods:
A hybrid operating room (OR) equipped with a robotic C-arm with integrated optical cameras for augmented reality instrument navigation was used. In two pig cadavers, cone beam computed tomography (CBCT) scans were performed, a 3D model generated, and pedicle screw insertions were planned. Seventy-eight insertions were performed. Technical accuracy was assessed on post-insertion CBCTs by measuring the distance between the navigated device and the corresponding pre-planned path as well as the angular deviations. Drilling and hammering into the pedicle were also compared. Navigation time was measured. An independent reviewer assessed a simulated clinical accuracy according to Gertzbein.
Results:
The technical accuracy was 1.7 ± 1.0 mm at the bone entry point and 2.0 ± 1.3 mm at the device tip. The angular deviation was 1.7 ± 1.7° in the axial and 1.6 ± 1.2° in the sagittal plane. Navigation time per insertion was 195 ± 93 seconds. There was no difference in accuracy between hammering and drilling into the pedicle. The clinical accuracy was 97.4% to 100% depending on the screw size considered for placement. No ionizing radiation was used during navigation.
Conclusion:
ARSN with instrument tracking for MISS is feasible, accurate, and radiation-free during navigation.
Level Of Evidence:
3.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Improving Translational Accuracy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Instrument Transformers
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...