Abstract:
The excessive cell death rate caused by electrofusion with unipolar pulses (UPs) has been a bottleneck to increasing cell fusion efficiency in monoclonal antibody technology. Several studies have confirmed that compared with UPs, bipolar pulses (BPs) with microsecond pulse widths can increase electropermeabilization while reducing cell death. Given these characteristics, BPs were used to increase cell fusion efficiency in this study. Cell staining and hybridoma culture experiments were performed using SP2/0 mouse myeloma cells and lymphocytes. Based on the equal energy principle, UPs and BPs were delivered to electrodes at a distance of 3.81 mm, with electric field intensities ranging from 2 kV/cm to 3 kV/cm and pulse duration of 40 μs for the UPs and 20-20 μs for the BPs. The results of cell staining experiments showed that cell fusion efficiency was 3-fold greater with BPs than with UPs. Similarly, the results of the hybridoma culture experiments showed that the hybridoma yields were 0.26‰ and 0.23‰ (2.5 kV/cm and 3 kV/cm, respectively) in the UP groups and increased to 0.46‰ and 0.35‰ in the BP groups. Taken together, the results show that the efficiency of heterologous cell fusion can be greatly increased if BPs are used instead of the commonly applied UPs. This study may provide a promising method for monoclonal antibody technology.
More Related Videos
09:45Production of Monoclonal Antibodies Targeting Aminopeptidase N in the Porcine Intestinal Mucosal Epithelium
Published on: May 18, 2021
04:46Changing the Direction and Orientation of Electric Field During Electric Pulses Application Improves Plasmid Gene Transfer in vitro
Published on: September 12, 2011
Related Concept Videos
Increased pulse rate
Many factors can elevate the risk of developing tachycardia. These include advanced age, a family history of arrhythmias, and an...
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Electric Field
In the new picture, imagine that the first charge sets up an electric field independent of all other charges in the universe. When another charge comes in its vicinity, the second charge experiences an electric force depending on the electric field at that point. The source charge does not...
Determining Electric Field From Electric Potential
In general, regardless of whether the electric field is uniform, it points in the direction of decreasing potential because the force on a positive...
Finding Electric Potential From Electric Field
Electric Field Lines
The solution to this problem is to use electric field lines, which are not vectors but...