Related Experiment Video
Updated: Jan 28, 2026

Characterization of Electrode Materials for Lithium Ion and Sodium Ion Batteries Using Synchrotron Radiation Techniques
Published on: November 11, 2013
Development of a long trace profiler in situ at National Synchrotron Radiation Research Center
Shang-Wei Lin1, Duan-Jen Wang1, Huang-Wen Fu1
1National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan.
Abstract:
To achieve an ultrahigh resolution of a beamline for soft X-rays at the Taiwan Photon Source (TPS), the profile of a highly precise grating is required at various curvatures. The slope error could be decreased to 0.1 µrad (rms) at a thermal load with a specially designed bender having 25 actuators. In the meantime, a long-trace profiler (LTP) was developed in situ to monitor the grating profile under a thermal load; it consists of a moving optical head, an air-bearing slide, an adjustable stand, and a glass viewport on the vacuum chamber. In the design of this system, a test chamber with an interior mirror was designed to simulate the chamber in the beamline. To prevent an error induced from a commercial viewport, a precision glass viewport (150CF, flatness 1/150 λ rms at 632.8 nm) was designed. The error induced from the slope error of the glass surface and the vacuum deformation was also simulated. The performance of the optical head of the LTP in situ (ISLTP) has been tested in the metrology laboratory. The sources of error of this LTP including the linearity and the glass viewport were corrected after the measurement. For the beamline measurement, an optical head was mounted outside the vacuum chamber; the measuring beam passed through the glass viewport to measure the grating profile in vacuum. The measurement of the LTP after correction of the above errors yielded a precision about 0.2 µrad (rms). In a preliminary test, an ISLTP was used to measure the grating profile at soft X-ray beamline TPS45A. The measured profile was for the bending mechanism to optimize the slope profile. From the measured energy spectrum, the slope error of the grating was estimated with software for optical simulation to be about 0.3 µrad (rms), consistent with our estimate of the ISLTP. In the future, it will be used to monitor the thermal bump under a large thermal load. In addition, an ISLTP was used to monitor the properties of optical elements-the twist and radius in the beamline during the installation phase.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
National Nursing Organizations I
National Nursing Organizations II
The AACN emphasizes a healthy work environment through six standards to achieve an optimal patient outcome. The standards are appropriate staffing, meaningful recognition, collaboration, authentic leadership, effective communication, and decision-making. In addition, AACN provides certification programs, webinars, journals, and...
Lattice Centering and Coordination Number
Types of Unit Cells
Imagine taking a large number of identical...
Center of Gravity
Center of Gravity
To determine its location, the principle of moments can be utilized by dividing the object into...

