Related Experiment Video
Updated: Jan 28, 2026

Biodegradable Magnesium Stent Treatment of Saccular Aneurysms in a Rat Model - Introduction of the Surgical Technique
Published on: October 1, 2017
Magnesium 2000 postmarket evaluation: Guideline adherence and intraprocedural performance of a sirolimus-eluting
Adrian Wlodarczak1, Luis Antonio Iñigo Garcia2, Pasi P Karjalainen3
1Department of Cardiology, MCZ Hospital, Lubin, Poland.
Background:
The Magmaris bioresorbable magnesium scaffold was successfully tested in in-vitro and in clinical premarket studies. Subsequently the Magmaris postmarket program aimed to review intraprocedural data of at least 2000 patients to assess user preferences, guideline adherence and intraprocedural performance in clinical routine.
Methods:
This international multicentre survey encompasses data from 356 hospitals across 45 countries. As part of the certification for Magmaris implantation, each hospital had to complete consecutive post-market evaluation forms of their first 10 commercial Magmaris patients.
Results:
From June 2016 to May 2018, data on 2018 implantations were collected. Main reasons for selecting Magmaris was patients' life expectancy (67%, n = 1359) and low or not calcified lesions, (67%, n = 1357). Magmaris was successfully deployed in 99% of cases (n = 1995), predilatation was performed in 95% (n = 1922) and post-dilatation in 87% (n = 1756). Physicians rated the overall performance and the pushability as good or very good in 96% of cases (n = 1799). Guide wire friction, trackability, and conformability were rated as good or very good in 94% of cases, and crossability in 93%. The majority of patients were scheduled to receive dual antiplatelet therapy for up to 12 months.
Conclusion:
Generally, implantation guidelines were adhered to and theoretical advantages of the metal scaffold observed in in-vitro tests have translated into practice with good intraprocedural performance outcomes, confirming the controlled roll-out of this novel technology into clinical practice.
Summary For Annotated Table Of Content:
The Magmaris 2000 program includes the first commercial cases at each hospital. Overall, data on 2018 implantations were collected. The high rate of pre- and post-dilatation as well as other parameters confirm that generally the implantation guidelines are adhered to and the good intraprocedural performance (rated as good or very good in 96%) confirm the theoretical advantages of a metallic scaffold in practice.
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Guidelines for Nursing Documentation II
Timely documentation is crucial to ensure continuity of care for patients. Any delays in recording or reporting medical information can result in medical errors and even adverse patient outcomes. From medication administration to diagnostic test results, every detail must be accurately and promptly documented to provide the best possible care for patients.
Legal Guidelines for Documentation
Guidelines for Sketching a Curve
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care...
Guidelines for Nursing Documentation I
Factual:
The following points emphasize the significance of upholding accurate and unbiased documentation in healthcare.

