Effect of Filtration and Slice Thickness of Cone-Beam Computed Tomography Images on Occlusal Caries Detection: An Ex
Mehrdad Abdinian1, Marzieh Ghaiour2
1Associate Professor, Dental Implant Research Center, Department of Oral and Maxillofacial Radiology, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.
Objectives:
The aim of this study was to evaluate the diagnostic accuracy of different filtrations and slice thicknesses of cone-beam computed tomography (CBCT) in the detection of occlusal caries.
Materials And Methods:
One-hundred teeth were selected for this ex-vivo experimental study. The CBCT images of the teeth were evaluated and scored by two observers in panoramic and cross-sectional views using different slice thicknesses and filtrations. Paired t-test, repeated-measures analysis of variance (ANOVA), and the least significant difference (LSD) test were used to compare the data with the histological gold standard. Receiver operating characteristic (ROC) analysis was used to determine the diagnostic accuracy of each slice thickness and filtration (P<0.05).
Results:
The mean score of true caries detection in cross-sectional views was lower than that in panoramic views (P<0.05). Repeated-measures ANOVA showed a significant difference in the mean of true detections in different thicknesses of cross-sectional views, but this difference was significant only between 5 mm thickness and other thicknesses in panoramic views. On all the views, increasing the thickness decreased the accuracy of caries detection. Repeated-measures ANOVA showed a significant difference between different filtrations; on all the views, increasing the filtration increased the accuracy of caries detection.
Conclusions:
An increase of filtration of CBCT images increases the accuracy of occlusal caries detection; however, an increase in slice thickness results in a lower diagnostic accuracy.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Filtration and Urine Formation
Glomerular Filtration: Net Filtration Pressure
GBHP, with an average value of 55 mmHg, promotes filtration by pushing water and solutes through the filtration membrane. This is balanced by two opposing forces: CHP, a "back pressure" exerted against the filtration membrane by fluid already in the capsular space and renal...
Filtration