Related Experiment Video
Updated: Jan 28, 2026

Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source
Published on: April 4, 2017
Time-Gated Ratiometric Detection with the Same Working Wavelength To Minimize the Interferences from Photon
Shengming Cheng1, Bin Shen1, Wei Yuan1
1Institutes of Biomedical Sciences & Department of Chemistry & State Key Laboratory of Molecular Engineering of Polymers, Fudan University, 220 Handan Road, Shanghai 200433, P. R. China.
Abstract:
Luminescence imaging, exhibiting noninvasive, sensitive, rapid, and versatile properties, plays an important role in biomedical applications. It is usually unsuitable for direct biodetection, because the detected luminescence intensity can be influenced by various factors such as the luminescent substance concentration, the depth of the luminescent substance in the organism, etc. Ratiometric imaging may eliminate the interference due to the luminescent substance concentration on the working signal. However, the conventional ratiometric imaging mode has a limited capacity for in vivo signal acquisition and fidelity due to the highly variable and wavelength-dependent scattering and absorption process in biotissue. In this work, we demonstrate a general imaging mode in which two signals with the same working wavelength are used to perform ratiometric sensing ignoring the depth of the luminescent substance in the organism. Dual-channel decoding is achieved by time-gated imaging technology, in which the signals from lanthanide ions and fluorescent dyes are distinguished by their different luminescent lifetimes. The ratiometric signal is proven to be nonsensitive to the detection depth and excitation power densities; thus, we could utilize the working curve measured in vitro to determine the amount of target substance (hypochlorous acid) in vivo.
Related Concept Videos
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
The de Broglie Wavelength
Interference and Diffraction
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
RNA Interference
This process occurs naturally in cells, often through the activity of genomically-encoded microRNAs. Researchers can take advantage of this mechanism by introducing synthetic RNAs to deactivate specific genes for research or therapeutic purposes. For example, RNAi could be used...
Detection of Gross Error: The Q Test

