Standardization of a Continuous Ramp Ergometer Protocol for Clinical Exercise Testing in Children
Jenna M Octavio1,2, Amanda L Folk3, Lauren Falini4
1Nemours Cardiac Center, Nemours/Alfred I. duPont Hospital for Children, P.O. Box 269, Wilmington, DE, 19899, USA.
Abstract:
Developing a standardized protocol for pediatric exercise laboratories is challenging. Our objective was to report normal pediatric values for a continuous non-steady state cycle ergometer ramp protocol to achieve 8-10 min of exercise based on sex and weight. One hundred seventeen patients (117) [mean age 13 ± 2.8 years, range 7-18 years (51% male)] referred for chest pain with normal cardiac evaluation underwent cardiopulmonary testing on a cycle ergometer. Patients entered one of the four continuous ramp protocols (10, 15, 20, and 25 W/min ramp) to achieve an expected peak workload of 3 W/kg at an increase of 0.3 to 0.35 W/kg/min. Exercise test outcomes measured included duration, peak heart rate, work, respiratory exchange ratio, peak oxygen consumption, peak blood pressure, and ventilatory anaerobic threshold. An exercise duration of 8-10 min was achieved in a majority of the study population; however, interactions with age (older, longer duration) and sex (males, longer duration) were present. Using our algorithm (0.3-0.35 W/kg × weight), we demonstrated four non-steady state ramp bike ergometer protocols (10, 15, 20, and 25 W/min) that can be applied to males and females of different ages and weights to achieve an exercise duration of 8-10 min.
More Related Videos
07:32Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Published on: June 8, 2017
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
Pericarditis II: Clinical Features and Diagnostic Tests
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Myocarditis II: Clinical Features and Diagnostic Tests
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis II: Clinical features and Diagnostic Tests
