CT Angiography of the Aorta: Contrast Timing by Using a Fixed versus a Patient-specific Trigger Delay
Ricarda Hinzpeter1, Matthias Eberhard1, Ralf Gutjahr1
1From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr 100, CH-8091 Zurich, Switzerland (R.H., M.E., T.P., B.K., H.A.); Siemens Healthcare, Forchheim, Germany (R.G., B.S., T.G.F.); Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Zurich, Switzerland (K.R.); and Department of Cardiovascular Surgery, University Hospital of Zurich, Zurich, Switzerland (M.L.).
Optimizing contrast timing in CT angiography of the aorta is crucial. Patient-specific trigger delays improve image quality and provide uniform contrast attenuation compared to fixed delays.
Area of Science:
- Radiology
- Medical Imaging
- Cardiovascular Imaging
Background:
- Optimal timing for contrast media bolus in CT angiography is challenging due to short scanner durations and patient variability.
- Accurate contrast timing is essential for effective CT angiography of the aorta.
Purpose of the Study:
- To compare contrast opacification in CT angiography of the aorta using fixed versus patient-specific individualized trigger delays for contrast media timing with bolus tracking.
Main Methods:
- Prospective study comparing two cohorts: fixed trigger delay (4 seconds) and individualized trigger delay (6.4-11.3 seconds) for CT angiography of the thoracoabdominal aorta.
- Objective and subjective image quality assessments were performed.
- Statistical analysis included Student t test and Wilcoxon-Mann-Whitney test.
Main Results:
- The individualized cohort showed significantly higher overall attenuation (486 HU vs 438 HU; P < .001) and uniform attenuation distribution.
- Contrast-to-noise ratio (P = .04) and subjective image quality (100% excellent/good vs 67%; P < .001) were superior in the individualized cohort.
- No significant difference in image noise was observed between the cohorts.
Conclusions:
- Patient-specific individualized trigger delay significantly enhances image quality in CT angiography of the aorta.
- Individualized trigger delay ensures uniform contrast attenuation, outperforming fixed delay protocols.
- This approach addresses challenges in contrast timing for modern CT scanners.
More Related Videos
08:41Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Related Concept Videos
Fixed Action Patterns
The Aorta
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...
The Arch of Aorta
Encircling the heart, the coronary arteries form a ring-like structure before...
Thoracic Aorta
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...