Related Experiment Video
Updated: Jan 28, 2026

Subdural Soft Electrocorticography ECoG Array Implantation and Long-Term Cortical Recording in Minipigs
Published on: March 31, 2023
Implantable Multi-Modality Probe for Subdural Simultaneous Measurement of Electrophysiology, Hemodynamics, and
Objective:
The purpose of this paper is to demonstrate how the integration of the multi-channel measurement capabilities of near-infrared spectroscopy (NIRS), electrocorticography (ECoG), and negative temperature coefficient thermistor sensors into a single device compact enough for subdural implantation can provide beneficial information on various aspects of brain cortical activity and prove a powerful medical modality for pre-, intra-, and post-operative diagnoses in neurosurgery.
Methods:
The development of a flexible multi-modal multi-channel probe for the simultaneous measurement of the NIRS, ECoG, and surficial temperature obtained from the cerebral cortex was carried out. Photoelectric bare chips for NIRS channels, miniature temperature-coefficient thermistors for measuring localized temperature variation, and 3-mm-diameter platinum plates for ECoG recording were assembled on a polyimide-based flexible printed circuit to create six channels for each modality. A conformal coating of Parylene-C was applied on all the channels except the ECoG to make the probe surface biocompatible.
Results:
As a first-in-human study, the simultaneous measurement capability of the multi-modality probe, with sufficient signal-to-noise ratio and accuracy, to observe pathological neural activities in subjects during surgery and post-operative monitoring, with no complications two weeks since the implantation, was confirmed.
Conclusion:
The feasibility of using a single device to assess the dynamic pathological activity from three different aspects was determined for human patients.
Significance:
The simultaneous and accurate multi-channel recording of electrical, hemodynamic, and thermographic cortical activities in a single device small enough for subdural implantation is likely to have major implications in neurosurgery and neuroscience.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Sensory Modalities
General senses refer to the broad category of sensory information detected by receptors in the body and can be further grouped into somatic and visceral senses. Somatic sensations include touch, pressure, temperature, and pain and are essential for navigating our environment and...
Drug Distribution: Volume of Distribution
F Distribution
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C...