Related Experiment Video
Updated: Jan 28, 2026

Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy
Published on: April 9, 2019
Diffusion-weighted MRI of the prostate without susceptibility artifacts: Undersampled multi-shot turbo-STEAM with
Andreas Merrem1, Sabine Hofer1, Ali Seif Amir Hosseini2
1Biomedizinische NMR, Max-Planck-Institut für biophysikalische Chemie, Göttingen, Germany.
Abstract:
The aim of this study was to develop and evaluate a clinically feasible approach to diffusion-weighted (DW) MRI of the prostate without susceptibility-induced artifacts. The proposed method relies on an undersampled multi-shot DW turbo-STEAM sequence with rotated radial trajectories and a multi-step inverse reconstruction with denoised multi-shot phase maps. The total acquisition time was below 6 min for a resolution of 1.4 × 1.4 × 3.5 mm3 and six directions at b = 600 s mm-2 . Studies of eight healthy subjects and two patients with prostate cancer were performed at 3 T employing an 18-channel body-array coil and elements of the spine coil. The method was compared with conventional DW echo-planar imaging (EPI) of the prostate. The results confirm that DW STEAM MRI avoids geometric distortions and false image intensities, which were present for both single-shot EPI (ssEPI) and readout-segmented EPI, particularly near the intestinal wall of the prostate. Quantitative accuracy of the apparent diffusion coefficient (ADC) was validated with use of a numerical phantom providing ground truth. ADC values in the central prostate gland of healthy subjects were consistent with those measured using ssEPI and with literature data. Preliminary results for patients with prostate cancer revealed a correct anatomical localization of lesions with respect to T2 -weighted MRI in both mean DW STEAM images and ADC maps. In summary, DW STEAM MRI of the prostate offers clinically relevant advantages for the diagnosis of prostate cancer compared with state-of-the-art EPI-based approaches. The method warrants extended clinical trials.
More Related Videos
Related Concept Videos
Apparent Weight and the Earth's Rotation
For an object on the Earth's equator, the net centripetal force that accounts for its rotation is the Earth's pull towards its center, or the weight minus the normal force that prevents it from piercing into the Earth's surface....
Diffusion
Diffusion
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: