Updated: Jan 28, 2026

Improving Strength, Power, Muscle Aerobic Capacity, and Glucose Tolerance through Short-term Progressive Strength Training Among Elderly People
Published on: July 5, 2017
Using Unilateral Strength, Power and Reactive Strength Tests to Detect the Magnitude and Direction of Asymmetry: A
Chris Bishop1, Paul Read2, Shyam Chavda3
1Faculty of Science and Technology, London Sports Institute, Middlesex University, London NW1 4RL, UK. C.Bishop@mdx.ac.uk.
Abstract:
The aims of the present study were to determine test-retest reliability for unilateral strength and power tests used to quantify asymmetry and determine the consistency of both the magnitude and direction of asymmetry between test sessions. Twenty-eight recreational trained sport athletes performed unilateral isometric squat, countermovement jump (CMJ) and drop jump (DJ) tests over two test sessions. Inter-limb asymmetry was calculated from both the best trial and as an average of three trials for each test. Test reliability was computed using the intraclass correlation coefficient (ICC), coefficient of variation (CV) and standard error of measurement (SEM). In addition, paired samples t-tests were used to determine systematic bias between test sessions and Kappa coefficients to report how consistently asymmetry favoured the same side. Within and between-session reliability ranged from moderate to excellent (ICC range = 0.70⁻0.96) and CV values ranged from 3.7⁻13.7% across tests. Significant differences in asymmetry between test sessions were seen for impulse during the isometric squat (p = 0.04; effect size = ⁻0.60) but only when calculating from the best trial. When computing the direction of asymmetry across test sessions, levels of agreement were fair to substantial for the isometric squat (Kappa = 0.29⁻0.64), substantial for the CMJ (Kappa = 0.64⁻0.66) and fair to moderate for the DJ (Kappa = 0.36⁻0.56). These results show that when asymmetry is computed between test sessions, the group mean is generally devoid of systematic bias; however, the direction of asymmetry shows greater variability and is often inter-changeable. Thus, practitioners should consider both the direction and magnitude of asymmetry when monitoring inter-limb differences in healthy athlete populations.
Related Concept Videos
Non-destructive Tests for Concrete Strength
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
The Equilibrium Binding Constant and Binding Strength
Strength and Heat of Hydration