Brachial Neuritis After Botulinum Toxin Injections for Cervical Dystonia: A Need for a Reappraisal?

Ilaria Cani1, Anna Latorre2,3, Carla Cordivari2,4

  • 1IRCCS Istituto delle Scienze Neurologiche di Bologna Bologna BO Italy.

Abstract

Related Concept Videos

Directly Acting Muscle Relaxants: Dantrolene and Botulinum Toxin01:26

Directly Acting Muscle Relaxants: Dantrolene and Botulinum Toxin

Directly acting muscle relaxants like dantrolene and botulinum toxin (BoNT) have distinct mechanisms and applications. Dantrolene, a hydantoin derivative, acts on the ryanodine receptor (RYR1) in skeletal muscle cells. RYR1 are calcium channels present at the sarcoplasmic reticulum membrane. In response to excitation, they release calcium ions from the sarcoplasmic reticulum to the cytosol. Calcium promotes actin-myosin-mediated contraction of muscles.
The binding of dantrolene to the RYR1...
1.2K
Types of Toxins01:36

Types of Toxins

Humans continually engage with an environment rich in potentially harmful chemicals. These are introduced to our bodies through inhalation, ingestion, or skin contact. These chemicals exist in various forms, such as air and environmental pollutants, agricultural chemicals, organic solvents, and heavy metals.
Air pollutants, primarily gases, pose significant threats to respiratory health, leading to conditions like hypoxia, lung cancer, and in extreme cases, death.
Environmental pollutants like...
3.6K
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
1.2K
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1.6K
Gas Chromatography: Sample Injection Systems01:08

Gas Chromatography: Sample Injection Systems

In gas chromatography, the sample is introduced as a vapor plug into the carrier gas stream for high efficiency and resolution. A microsyringe injects the sample solution into a heated sample port, vaporizing it and mixing it with the carrier gas. This process is important to ensure the sample is properly prepared for analysis. Thermally sensitive samples can be injected directly into the column and volatilized by slowly increasing the column temperature.
Two primary injection methods are used...
1.5K
Drug Accumulation During Multiple Dosing: Repetitive IV Injections01:21

Drug Accumulation During Multiple Dosing: Repetitive IV Injections

Calculating drug dosage and accumulation in multiple-dose regimens is crucial for achieving therapeutic efficacy while avoiding toxicity. This involves determining the plasma drug concentrations over time to optimize dosing schedules. The principle of superposition is fundamental in this process, allowing for the prediction of drug concentration in plasma following multiple doses based on single-dose data.The principle of superposition asserts that the plasma concentration-time curves from...
272