Image quality and diagnostic accuracy of complex-averaged high b value images in diffusion-weighted MRI of prostate
Hamed Kordbacheh1, Ravi Teja Seethamraju2, Elisabeth Weiland3
1Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, White 270, Boston, MA, 02114, USA.
Purpose:
To evaluate the impact of complex-averaging on image quality (IQ) and diagnostic accuracy of acquired and calculated high b value (aHBV, cHBV) images in diffusion-weighted prostate MRI.
Materials And Methods:
This retrospective study included 84 patients who underwent multiparametric prostate MRI at 3 Tesla without endorectal coil. DWIs were acquired at three different b values which included two lower b values (b = 50,900 s/mm2) and one higher b value (aHBV at 2000 s/mm2). The acquired data were postprocessed to generate two different types of trace-weighted images-using conventional magnitude-averaging and complex-averaging. Using lower b values (b = 50,900 s/mm2) from both conventional and complex-averaged image sets, cHBV images (b = 2000 s/mm2) and ADC maps were derived. All image sets were reviewed by two radiologists in different reading sessions to assess image quality and PIRADS. The diagnostic accuracy of different image sets for the detection of prostate lesions was performed by correlating PIRADS and Gleason scores.
Results:
Complex-averaging did not impact ADC values of the prostate lesions compared to magnitude-averaging (P = 0.08). Complex-averaging improved image quality of acquired high b value and calculated high b value images (P < 0.0001). Complex-averaging also improved the level of confidence (LOC) of the acquired high b value for both readers (P < 0.0001, P < 0.05), but only for reader A in calculated high b value (P < 0.0001). The image quality of calculated high b value images was not significantly different than acquired high b value images. The dataset combining complex-averaging and calculated high b value provided the highest diagnostic accuracy (but not statistically significant) for detection of the significant prostate lesion compared to the magnitude-averaged acquired high b value (79.55% vs. 72.73%; P = 0.317). The mean acquisition time for b = 2000 s/mm2 sequence (aHBV) was 6 min 30 s (± 1 min 16 s) out of a total of 28 min 31 s (± 4 min 26 s) for the entire mp-MRI protocol (approximately 25% of total scan time).
Conclusion:
Complex-averaging provides better image quality and level of confidence without significant impact on ADC values and diagnostic accuracy for detection of the significant prostate lesions . The calculated high b value images are also comparable to (and can substitute) the acquired high b value images which can help in reducing the imaging time.
Insights
Complex-averaging enhances image quality and confidence in diffusion-weighted prostate MRI, without affecting diagnostic accuracy for significant prostate lesions. Calculated high b-value images are a viable alternative to acquired ones, potentially reducing scan time.
Area of Science:
- Radiology
- Medical Imaging
- Oncology
Background:
- Diffusion-weighted MRI (DW-MRI) is crucial for prostate cancer detection.
- High b-value imaging and complex-averaging are advanced techniques to improve image quality.
Purpose of the Study:
- To assess the impact of complex-averaging on image quality (IQ) and diagnostic accuracy.
- To compare acquired high b-value (aHBV) and calculated high b-value (cHBV) images in prostate MRI.
Main Methods:
- Retrospective analysis of 84 prostate MRI scans (3 Tesla, no endorectal coil).
- Acquired DWIs at b=50, 900, and 2000 s/mm².
- Generated trace-weighted images using magnitude-averaging and complex-averaging; derived cHBV images and ADC maps.
Main Results:
- Complex-averaging significantly improved IQ and level of confidence for aHBV and cHBV images (P<0.0001).
- No significant impact on ADC values or diagnostic accuracy for detecting significant prostate lesions.
- cHBV images demonstrated comparable quality to aHBV images.
Conclusions:
- Complex-averaging enhances prostate MRI IQ and confidence without compromising diagnostic performance.
- cHBV images offer a comparable alternative to aHBV, potentially reducing overall scan time.
More Related Videos
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Uncertainty in Measurement: Accuracy and Precision
Diffusion
Improving Translational Accuracy
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
Average Acceleration