Related Experiment Video
Updated: Jan 28, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Preparation and characterization of molecularly imprinted solid-phase extraction column coupled with high-performance
1Department of Pharmacy, GuangDong Pharmaceutical University, GuangZhou 510006, People's Republic of China.
Abstract:
We synthesized a selective molecularly imprinted solid-phase extraction (MIP-SPE) column and established an extraction and enrichment method using this MIP-SPE column. By coupling with HPLC, we developed a new method to detect trace amounts of melamine in eggs. The MIP-SPE column was synthesized by in situ thermal-initiated polymerization using melamine as the template, methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker and azodiisobutyronitrile as the initiator. HPLC was used to evaluate the identification and enrichment capability of the MIP-SPE column and for the measurement of melamine in the sample. The melamine concentration exhibited an excellent linear relationship in the range of 0.1-25.0 µg ml-1 (r = 0.9983). The identification capability of the MIP-SPE column was apparently superior to that of the non-imprinted polymer solid-phase extraction column; an average enrichment factor of 46.8-fold (RSD = 3.5%) was obtained for 0.4 µg ml-1 melamine by the MIP-SPE column. When the MIP-SPE HPLC method was applied to the detection of melamine in eggs, an average recovery rate of 93.5-102.0% (RSD = 3.6-4.9%) and a limit of detection of 0.05 µg kg-1 were obtained. This method is simple, fast and cost-effective; thus, it can greatly simplify the pre-treatment of complex samples and can be used in the detection of residual melamine in eggs and other products.
More Related Videos
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
Published on: January 6, 2016
10:21Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Related Concept Videos
Molecular Comparison of Gases, Liquids, and Solids
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Molecular and Ionic Solids
Molecular Solids
Molecular crystalline solids, such as ice, sucrose (table sugar), and iodine, are solids that are composed of neutral molecules as their constituent units. These molecules are held together by weak intermolecular forces such as London dispersion forces, dipole-dipole interactions, or hydrogen bonds, which...
High-Performance Liquid Chromatography: Elution Process